Pulsed illumination spectral-domain optical coherence tomography for human retinal imaging.
نویسندگان
چکیده
We present pulsed illumination spectral-domain optical coherence tomography (SD-OCT) for in vivo human retinal imaging. We analyze the signal-to-noise (SNR) for continuous wave (CW) and pulsed illumination SD-OCT. The lateral beam scan motion is responsible for a SNR drop due to lateral scanning induced interference fringe washout. Pulsed illumination can reduce the SNR drop by shorter sample illumination time during the integration time of a camera. First, we demonstrate the SNR benefit of pulsed illumination over CW as function of lateral scan speed for a paper sample. Finally, we show better SNR in retinal images of a normal subject with pulsed illumination SD-OCT over CW at high lateral scanning speed.
منابع مشابه
Retinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography
Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...
متن کاملبررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک
Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...
متن کاملHigh-Speed Spectral-Domain Optical Coherence Tomography and In Vivo Human Eye Imaging
Spectral-domain optical coherence tomography (SD-OCT) is a cross-sectional imaging technique for biological tissues with high spatial resolutions. Owing to the superior sensitivity of SD-OCT over the conventional time-domain OCT (TD-OCT), it has undergone rapid development in the past few years and has proved to be a promising technique for clinical and biological applications. One limitation o...
متن کاملHybrid retinal imager using line-scanning laser ophthalmoscopy and spectral domain optical coherence tomography.
We demonstrate for the first time the integration of two technologies, Spectral Domain Optical Coherence Tomography (SDOCT) and Line-Scanning Laser Ophthalmoscopy (LSLO) into a single compact instrument that shares the same imaging optics and line scan camera for both OCT and LSLO imaging. Co-registered high contrast wide-field en face retinal LSLO and SDOCT images are obtained non-mydriaticall...
متن کاملEvaluation of Optical Coherence Tomography Angiography Findings in Patients with Branch Retinal Vein Occlusion
Purpose: To analyze the correlation of optical coherence tomography angiography (OCTA) findings with visual acuity (VA) in patients with branch retinal vein occlusion (BRVO). Methods: This cross-sectional study was performed on 20 eyes of 20 patients with unilateral BRVO involving the macula referred to the ophthalmology clinic of Rassoul Akram Hospital. OCTA imaging was conducted for all patie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 14 15 شماره
صفحات -
تاریخ انتشار 2006