Diagnostic accuracy of stress myocardial perfusion imaging compared to invasive coronary angiography with fractional flow reserve meta-analysis.

نویسندگان

  • Richard A P Takx
  • Björn A Blomberg
  • Hamza El Aidi
  • Jesse Habets
  • Pim A de Jong
  • Eike Nagel
  • Udo Hoffmann
  • Tim Leiner
چکیده

BACKGROUND Hemodynamically significant coronary artery disease is an important indication for revascularization. Stress myocardial perfusion imaging is a noninvasive alternative to invasive fractional flow reserve for evaluating hemodynamically significant coronary artery disease. The aim was to determine the diagnostic accuracy of myocardial perfusion imaging by single-photon emission computed tomography, echocardiography, MRI, positron emission tomography, and computed tomography compared with invasive coronary angiography with fractional flow reserve for the diagnosis of hemodynamically significant coronary artery disease. METHODS AND RESULTS The meta-analysis adhered to the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement. PubMed, EMBASE, and Web of Science were searched until May 2014. Thirty-seven studies, reporting on 4721 vessels and 2048 patients, were included. Meta-analysis yielded pooled sensitivity, pooled specificity, pooled likelihood ratios (LR), pooled diagnostic odds ratio, and summary area under the receiver operating characteristic curve. The negative LR (NLR) was chosen as the primary outcome. At the vessel level, MRI (pooled NLR, 0.16; 95% confidence interval [CI], 0.13-0.21) was performed similar to computed tomography (pooled NLR, 0.22; 95% CI, 0.12-0.39) and positron emission tomography (pooled NLR, 0.15; 95% CI, 0.05-0.44), and better than single-photon emission computed tomography (pooled NLR, 0.47; 95% CI, 0.37-0.59). At the patient level, MRI (pooled NLR, 0.14; 95% CI, 0.10-0.18) performed similar to computed tomography (pooled NLR, 0.12; 95% CI, 0.04-0.33) and positron emission tomography (pooled NLR, 0.14; 95% CI, 0.02-0.87), and better than single-photon emission computed tomography (pooled NLR, 0.39; 95% CI, 0.27-0.55) and echocardiography (pooled NLR, 0.42; 95% CI, 0.30-0.59). CONCLUSIONS Stress myocardial perfusion imaging with MRI, computed tomography, or positron emission tomography can accurately rule out hemodynamically significant coronary artery disease and can act as a gatekeeper for invasive revascularization. Single-photon emission computed tomography and echocardiography are less suited for this purpose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Performance of First-Pass Myocardial Perfusion Imaging without Stress with Computed Tomography (CT) Compared with Coronary CT Angiography Alone, with Fractional Flow Reserve as the Reference Standard

Coronary computed tomography angiography (CCTA) in combination with first-pass CT myocardial perfusion imaging (MPI) has a better diagnostic performance than CCTA alone, compared with invasive coronary angiography as the reference standard. The aim of this study was to investigate the additional diagnostic value of first-pass CT-MPI without stress for detecting hemodynamic significance of coron...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

Absolute flow or myocardial flow reserve for the detection of significant coronary artery disease?

OBJECTIVES We compared the accuracy of quantified myocardial flow reserve and absolute stress myocardial blood flow (MBF) alone in the detection of coronary artery disease (CAD). BACKGROUND Myocardial flow reserve, i.e. ratio of stress and rest flow, has been commonly used to detect CAD with many imaging modalities. However, it is not known whether absolute stress flow alone is sufficient for...

متن کامل

Diagnostic Accuracy of Gated-SPECT Myocardial Perfusion Imaging and Exercise Stress Test for Diagnosis of Coronary Artery Disease

Background and Objective:Accurate diagnosis of CAD using noninvasive procedures is of great importance. The aim of the study is to assess diagnostic accuracy of myocardial perfusion imaging and compare it with exercise stress test in order to decipher a more accurate and cost-effective method for CAD detection. Materials and Methods:Of 430 consecutive patients suspected with CAD, 104 performed...

متن کامل

Computed tomography stress myocardial perfusion imaging in patients considered for revascularization: a comparison with fractional flow reserve.

AIMS Adenosine stress computed tomography myocardial perfusion imaging (CTP) is an emerging non-invasive method for detecting myocardial ischaemia. Its value when compared with fractional flow reserve (FFR), a highly accurate index of ischaemia, is unknown. Our aim was to determine the diagnostic accuracy of CTP and its incremental value when used with computed tomography coronary angiography (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 2015