Evaluation of a new whole room indirect calorimeter specific for measurement of resting metabolic rate.

نویسندگان

  • Russell Rising
  • Kathryn Whyte
  • Jeanine Albu
  • Xavier Pi-Sunyer
چکیده

BACKGROUND The most common methods for obtaining human resting metabolic rate (RMR) use either a ventilated hood connected to a metabolic cart (VH_MC) or calculation by many prediction equations utilizing the person's height and weight. These methods may be inherently inaccurate. The objective of this study is to compare the accuracy for the measurement of RMR by three methods: a new whole room indirect calorimeter specific for this purpose (RMR_WRIC), VH_MC and calculation by the Mifflin equation (ME). First, the VH_MC (Vmax Encore 2900, Carefusion Inc, San Diego, CA) and RMR_WRIC (Promethion GA-6/FG-1, Sable Systems Intl, Las Vegas, NV) were subjected to 10, one-hour ethanol (99.8 % purity) and propane (99.5 % purity) combustion tests, respectively, for simulated metabolic measurements. Thereafter, 40 healthy adults (22 M/18 F, 78.0 ± 24.5 kg, BMI = 25.6 ± 4.8, age 36.6 ± 13.4 years) had one-hour RMR (kcal), ventilation (liters) rates of oxygen (VO2), carbon dioxide (VCO2) and RQ (VCO2/VO2) measured after a 12-h fast with both the VH_ MC and the RMR_WRIC in a randomized fashion. The resting state was documented by heart rate. The RMR was also calculated using the ME, which was compared to both the RMR_WRIC and the VH_MC. All simulated and human metabolic data were extrapolated to 24-h and analyzed (SPSS, Ver. 22). RESULTS Comparing stoichiometry to actual combustion, the VH_MC underestimated simulated RMR (p < 0.05), VO2 (p < 0.05), VCO2 (p < 0.05) and the RQ. Similarly the RMR_WRIC underestimated simulated RMR (p < 0.05) and VO2 while overestimating VCO2 and the RQ. There was much greater variability in the simulated metabolic data between combustion and the VH_MC as compared to that of the RMR_WRIC. With regards to the volunteers, the RMR, RQ, VO2 and VCO2 determined by the VH_MC tended to be lower in comparison to these measurements determined by the RMR_WRIC. Finally, RMR calculated utilizing the ME was significantly (p < 0.05) less than the RMR_WRIC but similar to that obtained by the VH_MC. CONCLUSION The RMR_WRIC was more accurate and precise than either the VH_MC or ME, which has implications for determining energy requirements for individuals participating in weight loss or nutrition rehabilitation programs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter- and intra-day test-retest reliability of the Cosmed Fitmate ProTM indirect calorimeter for resting metabolic rate

Background In order to make objective and intelligent decisions regarding caloric intake for fat loss/physique enhancement, one’s resting metabolic rate should be measured. It is important that the device used to measure resting metabolic rate be valid and reliable. Therefore, the purpose of this study was to establish the interand intra-day test-retest reliability of the Cosmed Fitmate ProTM i...

متن کامل

Reproducibility of resting metabolic rate measurement in children.

The aim of the present study was to determine the reproducibility of measurement of resting metabolic rate (RMR) using a ventilated-hood indirect calorimeter in children using a short protocol suitable for the outpatient setting or home visit. The protocol consisted of an overnight (10-12 h) fast, 5-10 min supine rest, 5-10 min 'settling in' under the ventilated hood, and 12-16 min of measureme...

متن کامل

Development of New Predictive Equations to Estimate Basal Metabolic Rrates in Iranian Adults: A Study Protocol

Background and Objectives: Studies indicate over-estimation of basal metabolic rate (BMR) using common equations for the Asian people. The present study aims to develop new predictive equations for the Iranian people and to compare these equations with commonly used formulas. Materials and Methods: Total, 150healthy subjects aged 18-60 yrare invited to the Laboratory of Nutrition Research, Nat...

متن کامل

Intra-individual variability and measurement noise in estimates of energy expenditure by whole body indirect calorimetry.

1. Four men were each studied continuously over 12 d in a whole-body calorimeter. Dietary intake and daily activities were kept constant throughout the study. 2. Day-to-day coefficients of variation in energy expenditure within subjects were found to be 1.97% over 24 h, 5.93% during basal metabolic rate measurement, 2.40% overnight and 3.22% in exercise. 3. The contribution of measurement syste...

متن کامل

A new approach for flow-through respirometry measurements in humans.

Indirect whole room calorimetry is commonly used in studies of human metabolism. These calorimeters can be configured as either push or pull systems. A major obstacle to accurately calculating gas exchange rates in a pull system is that the excurrent flow rate is increased above the incurrent flow rate, because the organism produces water vapor, which also dilutes the concentrations of respirat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nutrition & metabolism

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2015