Assay of phenytoin: adaptation of "EMIT" to the centrifugal analyzer.

نویسندگان

  • P R Finley
  • R J Williams
  • J M Byers
چکیده

7. Booker, H. E., and Darcey, B. A., Enzymatic ixnmunoassay vs. gas_liquid chromatography for determination of phenobarbital and diphenylhydantoin in serum. Clin. Chem. 21, 1766 (1975). 8. Wallace, J., Biggs, J., and Dahl, E. V., Determination of diphenyihydantoin by ultraviolet spectrophotometry. Anal. Chem. 37,410 (1965). 9. Dill, W. A., Chucot, L., Chang, T., and Glazko, A. J., Simplified benzophenone procedure for determination of diphenylhydantoin in plasma. Clin. Chem. 17, 1200 (1971). 10. Dill, W. A., and Glazko, A. J., Comments on the determination of diphenyihydantoin (cont.). Clin. Chem. 20, 915 (1974). Letter to the Editor. 11. Dill, W. A., and Glazko, A. J., Fluorometric assay of diphenylhydantoin in plasma or whole blood. Clin. Chem. 18,675 (1972). 12. Dill, W. A., Fluorometric assay of phenytoin. In Methods of Analysis of Anti-Epileptic Drugs. J. W. A. Meijer, H. Meinardi, C.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptation of EMIT drug assays to a random-access automated clinical analyzer.

Enzyme multiplied immunoassay technique (EMIT) assays for theophylline, carbamazepine, phenytoin, phenobarbital, valproic acid, acetaminophen, gentamicin and tobramycin, have been adapted to the Technicon RA-1000 random access analyzer. Working reagents are stable for a period of at least one week, and calibration need only be performed when preparing fresh reagents. Between-day precision range...

متن کامل

Adaptation of the EMIT serum digoxin assay to a mini-disc centrifugal analyzer.

We have modified the EMIT (Syva) serum digoxin assay for use with a mini-disc centrifugal analyzer. A minicomputer is used to control data acquisition, calculations, and readout for 14 cuvettes simultaneously. Thus, it is not necessary for time each individual assay manually or to plot calibration curves on graph paper. We use incubation times and dilutions similar to those used for the manual ...

متن کامل

Measurementof Plasma Phenytoinby EMIT Ifl the Monarch CentrifugalAnalyzer : Studies on the Eliminationof Within

We investigated the measurement of phenytoin in plasma by the EMIT#{174} method, in the Monarch centrifugal analyzer. When we used the standard protocol supplied by Instrumentation Laboratory, significant drift was observed across a full rotor loaded with 31 replicates of a single specimen. Although the cause remains obscure, the drift was eliminated by using a load-spin-reload-spin procedure. ...

متن کامل

Cost-effective assays for use in monitoring carbamazepine, phenobarbital, and phenytoin in serum.

Using Syva "EMIT" reagents and the Cobas Bio centrifugal analyzer, we have developed cost-effective assays for therapeutic drug monitoring of carbamazepine, phenobarbital, and phenytoin. With these optimized methods one can assay up to 2470 samples with a single 100-test EMIT kit with good precision and accuracy. Between-batch CVs, based on results of repeat analysis of routine patients' sample...

متن کامل

Enzyme immunoassays with the miniature centrifugal fast analyzer.

We studied the EMIT (Enzyme Multiplied Immunoassay Technique, Syva) procedures for the assay of phenytoin and phenobarbital in serum, adapting them to the miniature Centrifugal Fast Analyzer. For different concentrations of drug, each rate of reaction decreased continuously with time, tending to converge on a single common value. The rate was most affected by the concentration of drug almost im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 22 6  شماره 

صفحات  -

تاریخ انتشار 1976