Treatment outcomes of carotid artery stenting with two types of distal protection filter device

نویسندگان

  • Minoru Iko
  • Hiroshi Aikawa
  • Yoshinori Go
  • Kanji Nakai
  • Masanori Tsutsumi
  • Iwae Yu
  • Taichiro Mizokami
  • Kimiya Sakamoto
  • Ritsuro Inoue
  • Takafumi Mitsutake
  • Ayumu Eto
  • Hayatsura Hanada
  • Kiyoshi Kazekawa
چکیده

PURPOSE Preventing cerebral embolism from debris produced during carotid artery stenting (CAS) is important. This study compared the treatment outcomes of CAS using two types of filter-based embolic protection devices currently in use in Japan. MATERIALS AND METHODS We assessed 121 consecutive cases of CAS performed with FilterWire EZ™ between July 2010 and November 2012 and 37 consecutive cases of CAS performed with the Spider FX™ between November 2012 and June 2013. A Carotid Wallstent™ was used in all cases. The incidence of positive lesions on diffusion-weighted magnetic resonance imaging (DWI) and stroke were compared between the groups. RESULTS Postoperative DWI-positive lesions were observed in 38 (31.4%) and 14 (37.8%) patients in the FilterWire and Spider groups, respectively. In the FilterWire group, complications were transient ischemic attacks in 3 (2.5%) patients, cerebral infarction in 2 (1.7%) patients (1 patient each with minor and major stroke), and cerebral hemorrhage due to hyperperfusion syndrome in 1 (0.8%) patient. In the Spider group, except for cerebral infarction (minor stroke) in 1 (2.7%) patient, no complications were observed. No significant differences were observed in the incidence of complications between the groups. CONCLUSION FilterWire EZ and Spider FX are comparable in terms of treatment outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

Comparison of anti-embolic protection with proximal balloon occlusion and filter devices during carotid artery stenting: clinical and procedural outcomes

AIM The objective of this study was to compare the periprocedural and clinical outcomes after carotid artery stenting (CAS) with proximal protection devices versus with distal protection devices. MATERIAL AND METHODS Patients with internal carotid artery (ICA) stenosis undergoing CAS with cerebral embolic protection were randomly assigned to proximal balloon occlusion or distal filter protect...

متن کامل

Cerebral protection with filter devices during carotid artery stenting.

BACKGROUND Distal embolization of debris during percutaneous carotid artery stenting may result in neurological deficit. Filter devices for cerebral protection potentially reduce the risk of embolization. METHODS AND RESULTS Elective carotid stent implantation using 3 different types of distal filter protection devices was attempted in 88 consecutive lesions (84 patients) in the internal caro...

متن کامل

Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting.

OBJECTIVE The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. METHODS From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid arte...

متن کامل

Comparison of Flow Impairment during Carotid Artery Stenting Using Two Types of Eccentric Filter Embolic Protection Devices

We investigated the angiographic findings and the clinical outcomes after carotid artery stenting (CAS) using two different, eccentric filter embolic protection devices (EPDs). Between July 2010 and August 2015, 175 CAS procedures were performed using a self-expandable closed-cell stent and a simple eccentric filter EPD (FilterWire EZ in 86 and Spider FX in 89 procedures). The angiographic find...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2014