Perceptual and physiological heat strain: examination in firefighters in laboratory- and field-based studies.
نویسندگان
چکیده
Firefighting demands performing heavy muscular work under adverse and potentially dangerous conditions. Although the physiological and psychological responses to simulated firefighting activities have been described, the heat strain has not been characterised using standardised indices of exercise-heat strain. The purpose of the study is to describe the physiological and perceptual strain associated with working in personal protective equipment and performing simulated firefighting activities in a hot environment using recently developed strain indices (Physiological Strain Index (PhSI); Perceptual Strain Index (PeSI)). Data from two previously published studies (Smith et al. 1995, 2001) - one a laboratory-based study and one a field-based study - were re-analysed incorporating the strain indices. The laboratory study involved walking on a treadmill for 15 min while wearing three different clothing and equipment configurations. The field study involved three trials of standardised firefighting tasks in a live-fire training structure (mean trial length = 5.76 min). Heart rate, rectal temperature, thermal sensations and ratings of perceived exertion were collected in each study. PhSI and PeSI values were calculated using the formulae developed by Moran et al. (1998b) and Tikuisis et al. (2002), respectively. PhSI and PeSI increased significantly over time in both studies. Even relatively brief bouts of exercise while wearing heavy impermeable clothing or simulated firefighting activity in the heat results in moderate to high levels of heat strain as assessed by PhSI and PeSI.
منابع مشابه
اعتبار سنجی شاخص استرین ادراکی برای ارزیابی استرین گرمایی در شرایط گرم آزمایشگاهی
Introduction: The incidence of heat stress is one of the most common problems in work environments as well as many different industries. The exposure of workers to heat results in heat strain. The purpose of the present study was to validate the Perceptual Strain Index through determining its relationship to the Physiological Strain Index and the Wet Bulb Globe Temperature Index und...
متن کاملPerception or reality: Can thermal perceptions inform management of firefighters in the heat?
Accurately assessing the physiological status of firefighters during work in the heat is critical to ensuring their safety. Evaluating core temperatures (Tc) in the field is problematic due to cost and limitations in technology and accuracy. As such, fire services rely on individual perceptions of wellbeing. The present study aimed to establish whether perceptual responses measured using the pe...
متن کاملDesign and construction of evaporative local cooling coatings and evaluate their efficiency in improving some perceptual indicators in laboratory conditions
Introduction: One way to reduce the level of heat strain is to use personal evaporative cooling coats. such as the wrist, ankle, head and neck. The purpose of this study is to design, construct, and determine the cooling power of local cooling coatings and evaluate their efficiency in improving perceptual indicators in the laboratory. Materials and Methods: Initially, the design and constructio...
متن کاملبررسی استرس گرمایی در یک معدن روباز سنگ آهن و ارتباط آن با استرین فیزیولوژیکی
Introduction: Workers in open pit iron ore mines are exposed to heat stress which can cause health and safety problems. The purpose of this study was to evaluate heat stress among open-pit mine workers of iron ore based on Wet Bulb Globe Temperature (WBGT) index and also to investigate its relationship with physiological Strain. Material and Method: This cross-sectional study was conducted o...
متن کاملEffect of base layer materials on physiological and perceptual responses to exercise in personal protective equipment.
Ten men (non-firefighters) completed a 110 min walking/recovery protocol (three 20-min exercise bouts, with recovery periods of 10, 20, and 20 min following successive bouts) in a thermoneutral laboratory while wearing firefighting personal protective equipment over one of four base layers: cotton, modacrylic, wool, and phase change material. There were no significant differences in changes in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ergonomics
دوره 52 6 شماره
صفحات -
تاریخ انتشار 2009