Networked District Cooling Plant Offers Lower First and Operating Costs

نویسنده

  • Thomas Hartman
چکیده

Recent improvements in HVAC control networking technologies together with an improved understanding of the nature of cooling loads in buildings offer enormous potential improvements in the cost effectiveness of district cooling plants. By carefully coordinating the district cooling plant design with a digital controls network to the loads served, the following economic advantages over traditional district cooling concepts are possible: 1. A smaller sized and therefore less costly chiller plant will serve the load. 2. A significantly higher annual operating efficiency can be achieved. A district heating and cooling plant currently under design for a moderate sized mixed use community will utilize a fully networked control system. The network based controls permit the plant to respond to actual loads at each point of use, adjusting both flow and chilled water temperature to optimize the operating efficiency of the overall system at all times. Furthermore, the network permits distributed point of use management of cooling or heating shortages that might occur in the event of a component failure in the plant. This automatic network based management scheme will ensure that critical loads are maintained and no one load suffers disproportionately under such conditions, reducing the need for redundancy in the plant design. This paper focuses on the cooling portion of the plant. It discusses benefits arising from the synergy of incorporating the communication and control network as part of the chiller plant design. The background and design considerations are discussed to show how the principles can be applied to other district heating and/or cooling plant designs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Optimal Power Flow of Multiple Energy Carriers in Networked Multi-Carrier Microgrid

The future distribution network comprising different energy carriers will include small-scale energy resources (SSERs) and loads, known as a Networked multi-carrier microgrid (NMCMG). This concept not only leads to an efficient reduction in operation costs, but also encompasses the energy transformation between gas and electric networks at combined nodes, as well as district heating networks. I...

متن کامل

Modelling and Compensation of uncertain time-delays in networked control systems with plant uncertainty using an Improved RMPC Method

Control systems with digital communication between sensors, controllers and actuators are called as Networked Control Systems (NCSs). In general, NCSs encounter with some problems such as packet dropouts and network induced delays. When plant uncertainty is added to the aforementioned problems, the design of the robust controller that is able to guarantee the stability, becomes more complex. In...

متن کامل

Multi-start simulated annealing for dynamic plant layout problem

In today’s dynamic market, organizations must be adaptive to market fluctuations. In addition, studies show that material-handling cost makes up between 20 and 50 percent of the total operating cost. Therefore, this paper considers the problem of arranging and rearranging, when there are changes in product mix and demand, manufacturing facilities such that the sum of material handling and rearr...

متن کامل

Evaluation of Carbon Dioxide Emission Using Energy Analysis Approach : A Case Study of a District Cooling Plant

Absorption process is normally used for chilled water production at district cooling plants. Besides enhancing the efficiency of the plant, the process assists in reducing the emission of CO2 to the environment. The absorption system is also installed at a district cooling plant at Universiti Teknologi Petronas. The system is operated using waste heat from the gas turbine to produce chilled wat...

متن کامل

Analysis of Temporal and Spatial Temperature Gradients for IC Reliability

One of the most common causes of IC failure is interconnect electromigration (EM), which exhibits a rate that is exponentially dependent on temperature. As a result, EM rate is one of the major determinants of the maximum tolerable operating temperature for an IC and of resulting cooling costs. Previous EM models have assumed a uniform, typically worst-case, temperature. This paper presents a m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998