High-resolution Autocollimator Calibration Sysytem

نویسندگان

  • H. FUJIMOTO
  • T. WATANABE
چکیده

This paper describes high-resolution autocollimator calibration system in NMIJ. A goniometer system with nano-radian resolution provides precision rotation angles of a mirror attached on the rotation axis and rotation angles read by an autocollimator are compared to the set angles. The rotation angle is detected by a highprecision angle interferometer that observes motions of corner reflectors attached to the axis. The interferometer is calibrated to output absolute angles by a 24-sided optical polygon that is attached to the rotation axis. The performance of the system is verified by comparing the calibration curves of same autocollimator taken by this system and those taken by the national standard of NMIJ.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Error Separation for Wide Area Film Measurement

We wanted to use a multiple probes and white light interferometer to measure the surface profile of thin film. However, this system, as assessed with a scanning method, suffers from the presence of a moving stage and systematic sensor errors. In this paper, in order to separate measurement error caused by the moving stage and systematic sensor errors, the least squares analysis is applied to ac...

متن کامل

A simple method for high-precision calibration of long-range errors in an angle encoder using an electronic nulling autocollimator

We describe a simple method for high-precision rotary angle encoder calibration for longrange angular errors. By using a redesigned electronic nulling autocollimator, an opticalpolygon artifact is calibrated simultaneously with determining the encoder error function over a rotation of 2π rad. The technique is applied to the NIST vacuum double crystal spectrometer, which depends on precise measu...

متن کامل

Vertical Angle Calibration of a Theodolite

Theodolites are one of a wide range of geodetic measuring instruments used in the geodesy, surveying and civil engineering industry. They are used to perform accurate angle measurements in both horizontal and vertical planes. Testing and calibration of these instruments is quite a complicated task, especially their vertical angles. Calibration of horizontal angles can be performed relatively ea...

متن کامل

Methods for determining the effect of flatness deviations, eccentricity and pyramidal errors on angle measurements

In angle calibrations the uncertainty contributions of the autocollimator and index table are easily estimated as these uncertainties are well documented, but it is more difficult to determine the uncertainties associated with flatness deviations, eccentricity and pyramidal errors of the measuring faces. Deviations in the flatness of angle surfaces have been held responsible for the lack of agr...

متن کامل

Preliminary determination of G using the BIPM torsion strip balance

The BIPM is undertaking a determination of the Newtonian gravitational constant, G using a torsion balance with a thin, heavily loaded strip as the suspension element. This apparatus uses four 1.2 kg test masses and four 15.5 kg source masses to produce a gravitational torque of 2× 10−8 N m. A preliminary determination of G has been made with a relative standard uncertainty of about 1.7× 10−3, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012