Peak inspiratory flow through Turbuhaler in acute asthma.
نویسندگان
چکیده
Efficient use of dry powder inhalers, such as Turbuhaler, is dependent on the generation of adequate inspiratory flow. It is not clear whether patients with acute asthma are able to generate adequate flow. Peak inspiratory flow (PIF) was measured through an empty Turbuhaler, and without this device, in 99 adults presenting to hospital with acute exacerbations of asthma. Where possible, patients were studied prior to nebulized bronchodilator therapy. Mean (SD) forced expiratory volume in one second (FEV1) was 1.2 (0.7) L, forced vital capacity (FVC) 2.1(1.0) L and peak expiratory flow (PEF) 199 (92) L.min-1. PIF without Turbuhaler was 152 (77) L.min-1 and correlated with PEF (r = 0.69). PIF through Turbuhaler was 60 (20) L.min-1 and weakly correlated with PEF (r = 0.35), and with PIF without Turbuhaler (r = 0.43). Two patients failed to generate the minimum inspiratory flow (30 L.min) required for efficient use of Turbuhaler; both recorded 26 L.min-1. Acute asthma is associated with considerable inspiratory, as well as expiratory airflow limitation. The relationship between inspiratory and expiratory airflow is not strong enough to predict whether patients with severe acute asthma will have difficulty using dry powder inhalers efficiently. Despite this, 98% of patients in this study generated inspiratory flow through Turbuhaler which would allow a therapeutically active amount of bronchodilator drug to be delivered to the airways.
منابع مشابه
The impact of inspiratory effort on inspiratory flow through Turbuhaler in asthmatic patients.
To investigate the impact of the inhalation effort on the peak inspiratory flow through Turbuhaler, 100 asthmatics having a wide range of asthma severity (baseline forced expiratory volume in one second 28-127% of predicted normal) were studied. Each patient inhaled through four modifications of empty Turbuhaler inhalers, using first a "deep" inhalation and then a "forceful and deep" inhalation...
متن کاملPeak inspiratory flow and inspiratory vital capacity of patients with asthma measured with and without a new dry-powder inhaler device (Turbuhaler).
In 101 asthmatic adults with varying degrees of bronchial obstruction, lung function tests including peak inspiratory flow (PIF), inspiratory vital capacity (IVC), peak expiratory flow (PEF), forced vital capacity (FVC), and forced expiratory volume in one second (FEV1) measurements were made. Significant correlations between inspiratory and expiratory volumes were found. In most patients, PIF ...
متن کاملEffects of frusemide on human airway epithelium.
3. Dolovich M, Vanzielegham M, Hidinger K-G, Newhouse MT. Influence of inspiratory flow rate on the response to terbutaline sulphate inhaled via the Turbuhaler. Am Rev Respir Dis, 1988, 137, A433. 4. Engel T, Heinig JH, Madsen F, Weeke B, Nikander K. Peak inspiratory flow rate and inspiratory vital capacity of patients with asthma, measured with and wilhout Turbuhaler. Proceedings of European A...
متن کاملFine particle mass from the Diskus inhaler and Turbuhaler inhaler in children with asthma.
The study aimed to investigate dose consistency and particle distribution from the dry powder inhalers Diskus and Turbuhaler. Full profiles of inhalation pressure versus time were recorded in 18 4 yr old and 18 8 yr old asthmatic children through Diskus and Turbuhaler inhalers. These data were used in an inhalation profile simulator to assess drug delivery from both a Diskus inhaler and a Turbu...
متن کاملLung deposition from the Turbuhaler in children with cystic fibrosis.
Drug delivery to patients using dry powder inhalers, such as the Turbuhaler, is believed to be influenced by the inspiratory flow used. Clinical studies have indicated that this delivery system can be used effectively by children. However, it is not known how the total and weight-corrected dose delivered to the airways varies with age. A deposition study using technetium-99m (99mTc)-labelled bu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 8 11 شماره
صفحات -
تاریخ انتشار 1995