Noise in a Calorimeter Readout System Using Periodic Sampling
نویسنده
چکیده
Fourier transform analysis of the calorimeter noise problem gives quantitative results on a) the time-height correlation, b) the effect of background on optimal shaping and on the ENC, c) sampling frequency requirements, and d) the relation between sampling frequency and the required quantization error.
منابع مشابه
The Na62 Liquid Krypton Calorimeter Readout Module Published by Iop Publishing for Sissa the Na62 Liquid Krypton Calorimeter Readout Module Contents 1 Introduction 1 1.1 Na62 Detectors Layout 1 1.2 Na62 Trigger System 2
The NA62 experiment [1] at CERN SPS (Super Proton Synchrotron) accelerator will be focused on precision tests of the Standard Model via studies of ultra-rare decays of charged kaons. The high resolution Liquid Krypton (LKr) calorimeter of the former NA48 experiment [2], together with other detectors, will provide a photon-veto with hermetic coverage from zero out to large angles from the decay ...
متن کاملNoise Characterization of the ATLAS Tile Calorimeter Readout System
It is shown that the addition of a low pass RC filter to the current ATLAS Tile Calorimeter 3-in-1 card decreases the high frequency noise. A peak in the output voltage is found for 29 Mhz input noise but is filtered out by the same low pass filter.
متن کاملCalice Electromagnetic Calorimeter Readout Status
The CALICE Electromagnetic CALorimeter (ECAL) will be a silicon-tungsten sampling calorimeter [1] with 30 layers of silicon wafers, each containing an 18×18 array of diode pads, giving 9720 channels to be read out. The signal from each pad is amplified by a Very Front End (VFE) ASIC [2] which multiplexes the signals from 18 pads onto one output line. The silicon wafers and VFE chips are mounted...
متن کاملCALIBRATION AND MONITORING OF THE TILE HADRONIC CALORIMETER OF ATLAS WITH A 137Cs SOURCE
Monitoring and intercalibration of the ATLAS TileCal is based on a hydraulically driven gamma source system. Extensive R&D has been carried out and has led to a detailed design for the full ATLAS TileCal. A prototype system has been built and tested on the Barrel and Extended Barrel modules. The realisation of the Cs source system, results concerning its performance, comparisons with other cali...
متن کاملNeutrino Lepton Physics with the CHARM2 Dttector
To match these requirements CHARM2 [2] has been built !as a high mass,low 2, high granularity, sampling calorimeter (total mass 692 tons). The calorimeter is made of 420 modules, each module consisting of a 3.7 m 'X 3.7 m, 4.8 cm thick, glass plate and of a plane of 352 plastic limited streamer Fubes with digital readout of the wires and analog readout of pickup strips orthogonal to the wires. ...
متن کامل