High-Cycle Fatigue of Single-Crystal Silicon Thin Films
نویسندگان
چکیده
When subjected to alternating stresses, most materials degrade, e.g., suffer premature failure, due to a phenomenon known as fatigue. It is generally accepted that in brittle materials, such as ceramics, fatigue can only take place in toughened solids, i.e., premature fatigue failure would not be expected in materials such as single crystal silicon. The results of this study, however, appear to be at odds with the current understanding of brittle material fatigue. Twelve thin-film ( 20 m thick) single crystal silicon specimens were tested to failure in a controlled air environment (30 0.1 C, 50 2% relative humidity). Damage accumulation and failure of the notched cantilever beams were monitored electrically during the “fatigue life” test. Specimen lives ranged from about 10 s to 48 days, or 1 106 to 1 1011 cycles before failure over stress amplitudes ranging from approximately 4 to 10 GPa. A variety of mechanisms are discussed in light of the fatigue life data and fracture surface evaluation. [642]
منابع مشابه
Effect of growth time on ZnO thin films prepared by low temperature chemical bath deposition on PS substrate
ZnO thin films were successfully synthesized on a porous silicon (PS) substrate by chemical bathdeposition method. X-ray diffraction (XRD), field-emission scanning electron microscopy (FESEM),and photoluminescence (PL) analyses were carried out to investigate the effect of growth duration(3, 4, 5, and 6 h) on the optical and structural properties of the aligned ZnO nanorods. T...
متن کاملResponse of Thin Films and Substrate to Micro-Scale Laser Shock Peening
Micro-scale laser shock peening LSP can potentially be applied to metallic structures in microdevices to improve fatigue and reliability performance. Copper thin films on a single-crystal silicon substrate are treated by using LSP and characterized using techniques of X-ray microdiffraction and electron backscatter diffraction (EBSD). Strain field, dislocation density, and microstructure change...
متن کاملHigh-cycle Fatigue in Micron-scale Structural Films of Polycrystalline Silicon: a Reaction-layer Failure Mechanism
A study has been made of high-cycle fatigue in 2-μm thick structural films of ntype, polycrystalline silicon for MEMS applications. Using an “on-chip” test structure resonating at ~40 kHz, such thin-film polysilicon is shown to display “metal-like” stress-life fatigue behavior in room air environments, with failures occurring after lives in excess of 10 cycles at stresses as low as half the fra...
متن کاملA reaction-layer mechanism for the delayed failure of micron-scale polycrystalline silicon structural films subjected to high-cycle fatigue loading
A study has been made to discern the mechanisms for the delayed failure of 2-μm thick structural films of n+-type, polycrystalline silicon under high-cycle fatigue loading conditions. Such polycrystalline silicon films are used in smallscale structural applications including microelectromechanical systems (MEMS) and are known to display ‘metal-like’ stress-life (S/N) fatigue behavior in room te...
متن کاملFurther considerations on the high-cycle fatigue of micron-scale polycrystalline silicon
Bulk silicon is not susceptible to high-cycle fatigue but micron-scale silicon films are. Using polysilicon resonators to determine stress-lifetime fatigue behavior in several environments, oxide layers are found to show up to four-fold thickening after cycling, which is not seen after monotonic loading or after cycling in vacuo.We believe that the mechanism of thin-film silicon fatigue is ‘‘re...