Two Legionnaires' disease cases associated with industrial waste water treatment plants: a case report

نویسندگان

  • Jaana Kusnetsov
  • Liisa-Kaarina Neuvonen
  • Timo Korpio
  • Søren A Uldum
  • Silja Mentula
  • Tuula Putus
  • Nhu Nguyen Tran Minh
  • Kari-Pekka Martimo
چکیده

BACKGROUND Finnish and Swedish waste water systems used by the forest industry were found to be exceptionally heavily contaminated with legionellae in 2005. CASE PRESENTATION We report two cases of severe pneumonia in employees working at two separate mills in Finland in 2006. Legionella serological and urinary antigen tests were used to diagnose Legionnaires' disease in the symptomatic employees, who had worked at, or close to, waste water treatment plants. Since the findings indicated a Legionella infection, the waste water and home water systems were studied in more detail. The antibody response and Legionella urinary antigen finding of Case A indicated that the infection had been caused by Legionella pneumophila serogroup 1. Case A had been exposed to legionellae while installing a pump into a post-clarification basin at the waste water treatment plant of mill A. Both the water and sludge in the basin contained high concentrations of Legionella pneumophila serogroup 1, in addition to serogroups 3 and 13. Case B was working 200 meters downwind from a waste water treatment plant, which had an active sludge basin and cooling towers. The antibody response indicated that his disease was due to Legionella pneumophila serogroup 2. The cooling tower was the only site at the waste water treatment plant yielding that serogroup, though water in the active sludge basin yielded abundant growth of Legionella pneumophila serogroup 5 and Legionella rubrilucens. Both workers recovered from the disease. CONCLUSION These are the first reported cases of Legionnaires' disease in Finland associated with industrial waste water systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outbreak of legionnaires' disease from a cooling water system in a power station.

In September and October 1981 six cases of pneumonia occurred among men working in a power station under construction. Three were identified as cases of legionella pneumonia and two others had serology suggestive of legionella infection. In a sample of 92 men from the site 10 had low levels of antibodies to legionella; a similar sample of men working on an adjacent site showed none with positiv...

متن کامل

A Case Report of Severe Legionnaires’ Disease in Tehran, Iran

Legionella pneumophila is a thin, aerobic, Gram-negative, pathogenic bacillus and the leading cause of Legionnaires’ disease (LD) in human, especially those with high risk conditions including immune system disorders or chronic lung diseases. The mortality rate of LD has been reported to be 60% or higher in inappropriately treated cases. Investigating the prevalence of L. pneumophila and identi...

متن کامل

Potable water as a cause of sporadic cases of community-acquired legionnaires' disease.

BACKGROUND The environmental sources of sporadic, community-acquired legionnaires' disease are largely unknown, and culturing of water sources after identification of a case is currently not recommended. We conducted a prospective study of sporadic cases of community-acquired legionnaires' disease to determine whether the environmental reservoirs could be identified. METHODS We cultured sampl...

متن کامل

Detection of Legionella by cultivation and quantitative real-time polymerase chain reaction in biological waste water treatment plants in Norway.

Cases of Legionnaires' disease associated with biological treatment plants (BTPs) have been reported in six countries between 1997 and 2010. However, knowledge about the occurrence of Legionella in BTPs is scarce. Hence, we undertook a qualitative and quantitative screening for Legionella in BTPs treating waste water from municipalities and industries in Norway, to assess the transmission poten...

متن کامل

Legionnaires’ disease after using an industrial pressure test pump: a case report

INTRODUCTION Legionnaires' disease is an acute pneumonia caused by inhalation or aspiration of aerosols contaminated with Legionella bacteria. The majority (>90%) of Legionnaires' disease cases are caused by the species Legionella pneumophila, and about 85% more specifically by L. pneumophila serogroup 1 that can be detected by a fast and easy to perform urinary antigen test. Previously reporte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010