Femoral Neck Version Affects Medial Femorotibial Loading
نویسندگان
چکیده
The aim of this study was to provide a preliminary evaluation of the possible effect that femoral version may have on the bearing equilibrium conditions developed on the medial tibiofemoral compartment. A digital 3D solid model of the left physiological adult femur was used to create morphological variations of different neck-shaft angles (varus 115, normal 125, and valgus 135 degrees) and version angles (-10, 0, and +10 degrees). By means of finite element modeling and analysis techniques (FEM-FEA), a virtual experiment was executed with the femoral models aligned in a neutral upright position, distally supported on a fully congruent tibial tray and proximally loaded with a vertical only hip joint load of 2800 N. Equivalent stresses and their distribution on the medial compartment were computed and comparatively evaluated. Within our context, the neck-shaft angle proved to be of rather indifferent influence. Reduction of femoral version, however, appeared as the most influencing parameter regarding the tendency of the medial compartment to establish its bearing equilibrium towards posteromedial directions, as a consequence of the corresponding anteroposterior changes of the hip centre over the horizontal tibiofemoral plane. We found a correlation between femoral anteversion and medial tibiofemoral compartment contact pressure. Our findings will be further elucidated by more sophisticated FEM-FEA and by clinical studies that are currently planned.
منابع مشابه
Femoral and Tibial Condyle Bone Mineral Densities in Women with Symptomatic Knee Osteoarthritis
INTRODUCTION: Abnormal medial loading results in decreased cartilage thickness, osteophyte ingrowths, and subchondral bone sclerosis of the medial femoral and tibial condyles in patients with medial knee osteoarthritis (OA). Among these changes, subchondral bone sclerosis may reflect altered mechanical loading. However, sclerosis of the knee condyles remains difficult to visually discern on rad...
متن کاملPosition of hip resurfacing component affects strain and resistance to fracture in the femoral neck.
BACKGROUND Retrieval studies have suggested that the cause of femoral implant failure after metal-on-metal hip resurfacing is multifactorial. Both varus positioning of the femoral component and notching of the superior part of the femoral neck have been associated with femoral component failure. The hypotheses of this study were that placement of a femoral resurfacing component alters femoral n...
متن کاملPatellofemoral contact patterns before and after total knee arthroplasty: an in vitro measurement
BACKGROUND Patellofemoral complications are one of the main problems after Total Knee Arthroplasty (TKA). Retropatellar pressure distribution after TKA can contribute to these symptoms. Therefore we evaluated retropatellar pressure distribution subdivided on the ridge, medial and lateral surface on non-resurfaced patella before and after TKA. Additionally, we analyzed axial femorotibial rotatio...
متن کاملClinical Outcomes of Patients with Valgus Deformity Undergoing Minimally Invasive Total Knee Arthroplasty Through the Medial Approach
OBJECTIVE The purpose of this study was to compare the clinical outcomes between patients with a valgus or varus deformity undergoing minimally invasive total knee arthroplasty through the medial approach. METHODS The patients were classified into 2 groups according to the preoperative femorotibial angle measured on an anteroposterior long leg roentgenogram. The valgus group comprised of 26 k...
متن کاملInternal femoral forces and moments during running: implications for stress fracture development.
BACKGROUND Femoral stress fractures tend to occur at the neck, medial proximal-shaft, and distal-shaft. The purpose of this study was to determine the internal femoral forces and moments during running. It was expected that larger loads would occur at these common sites of femoral stress fracture. METHODS Ten subjects ran at their preferred running speed over a force platform while motion cap...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2013 شماره
صفحات -
تاریخ انتشار 2013