Diagnosis of congenital obstructive aortic arch anomalies in Chinese children by contrast-enhanced magnetic resonance angiography.

نویسندگان

  • Zhu Ming
  • Zhong Yumin
  • Li Yuhua
  • Jin Biao
  • Sun Aimin
  • Wang Qian
چکیده

OBJECTIVE The purpose of this study was to evaluate the accuracy of contrast-enhanced magnetic resonance angiography for the diagnosis of congenital obstructive aortic arch anomalies in children and compare it with transthoracic echocardiography and other MR imaging techniques (ECG gated T1-weighted spin-echo imaging and gradient-echo cine imaging). MATERIALS AND METHODS Contrast-enhanced magnetic resonance angiography, ECG gated T1-weighted spin-echo imaging, and gradient-echo cine imaging were performed for the diagnosis of congenital obstructive aortic arch anomalies in 416 patients from April 1999 to March 2005 (age range, 3 days to 12 years; mean age, 2.4 years) using a GE 1.5T MR scanner. Transthoracic echocardiography was performed in all patients prior to MR examination. Surgery and/or conventional X-ray angiocardiography were done in all patients to determine the final diagnosis. RESULTS The population consisted of 416 patients. Congenital obstructive aortic arch anomalies were diagnosed in 213 patients and ruled out in 203 patients by operation and/or conventional X-ray angiocardiography. Among the 213 patients with anomalies, coarctation of aorta was diagnosed in 174, interruption of aortic arch was diagnosed in 35, and persistent fifth aortic arch with fourth aortic arch interruption was diagnosed in 4 patients. Among the 35 patients with interruption of aortic arch, 21 were of type A, and 14 were of type B. The diagnostic sensitivity, specificity and accuracy of contrast-enhanced magnetic resonance angiography for congenital obstructive aortic arch anomalies were 98% (208/213), 99% (201/203) and 98% (409/416), respectively. The diagnostic sensitivity, specificity and accuracy of transthoracic echocardiography were 88% (187/213), 92% (186/203) and 90% (373/416), respectively. The diagnostic sensitivity, specificity and accuracy of other MR imaging techniques (ECG gated T1-weighted spin-echo imaging and gradient-echo cine imaging) were 89% (189/213), 84% (170/203) and 86% (359/416), respectively. CONCLUSION Contrast-enhanced magnetic resonance angiography is a reliable, noninvasive imaging technique for the diagnosis of congenital obstructive aortic arch anomalies in children. Occasionally, even more information can be obtained from this technique than from conventional X-ray angiocardiography. Contrast-enhanced magnetic resonance angiography is superior to transthoracic echocardiography and other MR imaging techniques (ECG gated T1-weighted spin-echo imaging and gradient-echo cine imaging) for diagnosis of congenital obstructive aortic arch anomalies in children.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal values for aortic diameters in children and adolescents – assessment in vivo by contrast-enhanced CMR-angiography

BACKGROUND Contrast-enhanced CMR angiography (CE-CMRA) is being increasingly used for diagnosing aortic arch anomalies, planning interventions and follow-up assessment. We sought to establish normal values for the diameters of the thoracic aorta and reference curves related to body growth in children using CE-CMRA. RESULTS CE-CMRA was performed in 53 children without cardiovascular disease. T...

متن کامل

Stridor in a Newborn with Double Aortic Arch-A Case Report

Introduction: Double aortic arch (DAA) is a congenital anomaly of the aortic arch. It is the most common type of complete vascular ring. When it occurs, the connected segment of the aortic arch and its branches encircle the trachea and esophagus, leading to symptoms related to these two structures. Case Report: We present a case of a newborn baby who developed biphasic stridor immediately after...

متن کامل

Three Cases of a Rare Association: Double Aortic Arch

Background Vascular ring is less than 1% of congenital heart disease. Double aortic arch (DAA) is the most common form of it.  Its detecting is important because of the effects of pressure on the esophagus and trachea. Case Report In this study, three children suffering from double aortic arch with symptoms of dysphagia and recurrent aspiration, which in two cases had led to cardiac arrest, wer...

متن کامل

Three-Dimensional Time-of-Flight Magnetic Resonance Angiography Detection of Duplication of the Vertebral Artery in a Large Chinese Population

BACKGROUND The aim of this study was to investigate duplication of the vertebral artery (VA) using three-dimensional time-of-flight (3D TOF) magnetic resonance angiography (MRA) in a large study population to further our understanding of vascular variations. MATERIAL AND METHODS A retrospective analysis of 3D TOF-MRA data in 12 826 cases was performed. The occurrence rate of VA duplication was ...

متن کامل

Interrupted Aortic Arch in an adult.

Interrupted aortic arch (IAA) is a rare congenital abnormality with only a few cases reported in adults. It is defined as complete loss of continuity between the ascending and descending portions of the aorta, and is usually associated with other cardiac defects. The diagnosis in adults should be suspected in the presence of refractory hypertension, a careful physical examination being crucial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 8 5  شماره 

صفحات  -

تاریخ انتشار 2006