Performance of Digital Radiographic Detectors: Quantification and Assessment Methods

نویسنده

  • Ehsan Samei
چکیده

Digital radiographic systems are gaining widespread use in many clinical applications. Digital radiographic detectors vary dramatically with respect to the technologies that they use and the particular implementation. Their performance thus varies from system to system. It is often necessary to characterize the performance of a digital radiographic or mammographic detector for optimization, design, comparison, or quality assurance purposes. To do so, it is most useful to measure the performance of the detector in terms of common performance metrics, so that meaningful comparisons can be made. The performance of a digital radiographic detector can be described in terms of a number of performance factors. Among them, sharpness and noise are two key characteristics that describe the intrinsic image quality performance of digital radiographic systems (1,2). Together, these two, along with an associated characteristic, the signal-to-noise ratio (SNR), define the intrinsic ability of an imaging system to faithfully represent the anatomic features of the body part being imaged. This chapter first focuses on the quantification of sharpness, noise, and SNR in radiographic systems in terms of common performance metrics of the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE). Methods for measuring the MTF, the NPS, and the DQE are then described. The chapter ends with an outline of detector performance factors that may be considered in a comprehensive evaluation of the performance of a detector. The next chapter in the syllabus focuses on the factors that influence the sharpness and noise performance of a digital radiographic detector.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

Radiographic comparison of the repaired bone in maxillary alveolar cleft of dog by tissue engineering and autogenous bone grafting techniques

BACKGROUND: Dental disease, trauma and maxillofacial surgeries can cause alveolar bone defects. Among different kinds of treatment, autogenous bone grafts is accepted as a golden standard. On the other hand, because of limitation of treatment with autogenous bone grafts, osteogenic cells derived from stem cells are suggested. OBJECTIVES: The aim of this study was to compare the mean density of ...

متن کامل

Effective Dose Evaluation of Critical Organes in Digital Radiography Exames

Background and Aim: Due to the increasing number of radiographic tests, TLD dosimeters can be used to measure the effective dose of critical organs in various radiographic tests. In this research, the progression of analogue to digital radiology devices, which facilitates and accelerates the performance of radiographs, especially emergency patients, was investigated, and then the effective dose...

متن کامل

بررسی میزان تکرار تصاویر رادیوگرافی دیجیتال و عوامل مرتبط با آن در مراکز درمانی بخش های دولتی شهرستان ساری در سال 1396

  Background and purpose: The radiographic imaging repeat rate (RR) in digital and conventional imaging systems is considered as a quality control indicator. RR increases the unnecessary patient and staff dose, prevents the loss of resources and depreciation of systems and increases the time for radiographic services. In this study, digital radiographic RR and its related factors were inv...

متن کامل

A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography

Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001