A Constant-Force Technique to Measure Corneal Biomechanical Changes after Collagen Cross-Linking
نویسندگان
چکیده
PURPOSE To introduce a constant-force technique for the analysis of corneal biomechanical changes induced after collagen cross-linking (CXL) that is better adapted to the natural loading in the eye than previous methods. METHODS For the biomechanical testing, a total of 50 freshly enucleated eyes were obtained and subdivided in groups of 5 eyes each. A Zwicki-Line Testing Machine was used to analyze the strain of 11 mm long and 5 mm wide porcine corneal strips, with and without CXL. Before material testing, the corneal tissues were pre-stressed with 0.02 N until force stabilization. Standard strip extensiometry was performed as control technique. For the constant-force technique, tissue elongation (Δ strain, %) was analyzed for 180 seconds while different constant forces (0.25 N, 0.5 N, 1 N, 5 N) were applied. RESULTS Using a constant force of 0.5 N, we observed a significant difference in Δstrain between 0.26±0.01% in controls and 0.12±0.03% in the CXL-treated group (p = 0.003) over baseline. Similarly, using a constant force of 1 N, Δstrain was 0.31±0.03% in controls and 0.19±0.02% after CXL treatment (p = 0.008). No significant differences were observed between CXL-treated groups and controls with 0.25 N or 5 N constant forces. Standard stress-strain extensiometry failed to show significant differences between CXL-treated groups and controls at all percentages of strains tested. CONCLUSION We propose a constant-force technique to measure corneal biomechanics in a more physiologic way. When compared to standard stress-strain extensiometry, the constant-force technique provides less variability and thus reaches significant results with a lower sample number.
منابع مشابه
Cross-Linking of Corneal Collagen with UVA and Riboflavin for the Treatment of Corneal Disease
Introduction In recent years, reduced corneal biomechanics have been identified as an important element in the pathogenesis of various corneal diseases. The biomechanical characteristics of a connective tissue such as strength and resistance against mechanical stress are indispensable prerequisites to maintain regular shape and function of that tissue. Intraand intermolecular cross-links betwee...
متن کاملComparative Study of the Effect of Indomethacin and Acetaminophen on Pain after Collagen Cross-Linking Surgery
Introduction: One of the surgeries that needs to be considered after pain and discomfort is corneal cross-linking of the cornea. The aim of this study was to compare the effect of indomethacin and acetaminophen oral surgery before surgery on postoperative pain in the patients undergoing collagen cross-linking surgery. Methods: The present study was a double-blind clinical trial study that was ...
متن کاملAcoustic radiation force for noninvasive evaluation of corneal biomechanical changes induced by cross-linking therapy.
OBJECTIVES To noninvasively measure changes in corneal biomechanical properties induced by ultraviolet-activated riboflavin cross-linking therapy using acoustic radiation force (ARF). METHODS Cross-linking was performed on the right eyes of 6 rabbits, with the left eyes serving as controls. Acoustic radiation force was used to assess corneal stiffness before treatment and weekly for 4 weeks a...
متن کاملCorneal Collagen Cross-Linking Outcomes: Review
Keratoconus is a condition characterized by biomechanical instability of the cornea, presenting in a progressive, asymmetric and bilateral way. Corneal collagen cross-linking with riboflavin and UVA (CXL) is a new technique of corneal tissue strengthening that combines the use of riboflavin as a photo sensitizer and UVA irradiation. The studies showed that CXL was effective in halting the progr...
متن کاملIn vivo biomechanical changes after corneal collagen cross-linking for keratoconus and corneal ectasia: 1-year analysis of a randomized, controlled, clinical trial.
PURPOSE To investigate the in vivo, corneal, biomechanical changes after corneal collagen cross-linking (CXL) using the Ocular Response Analyzer (ORA) in patients with keratoconus and post-laser in situ keratomileusis (LASIK) ectasia. METHODS Single-center, prospective, randomized, controlled, clinical trial. After CXL (69 eyes, 46 keratoconus and 23 post-LASIK), corneal hysteresis (CH) and c...
متن کامل