Determination of Trace Anions in Concentrated Hydrogen Peroxide by Direct Injection Ion Chromatography with Conductivity Detection after Pt-Catalyzed On-Line Decomposition

نویسندگان

  • Do-Hee Kim
  • Bo-Kyung Lee
  • Dong Soo Lee
چکیده

A method has been developed for the determination of trace anion impurities in concentrated hydrogen peroxide. The method involves on-line decomposition of hydrogen peroxide, ion chromatographic separation and subsequent suppressed-type conductivity detection. H2O2 is decomposed in Pt-catalyst filled Gore-Tex membrane tubing and the resulting aqueous solution containing analytes is introduced to the injection valve of an ion chromatograph for periodic determinations. The oxygen gas evolving within the membrane tubing escapes freely through the membrane wall causing no problem in ion chromatographic analysis. Decomposition efficiency is above 99.99% at a flow rate of 0.4mL/min for a 30% hydrogen peroxide concentration. Analytes are quantitatively retained. The analysis results for several brands of commercial hydrogen peroxides are reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of anions at trace levels in power plant water samples by ion chromatography with electrolytic eluent generation and suppression.

An ion chromatographic method was developed for the determination of nine inorganic and organic acid anions at sub- to low-microg/l levels in power plant water samples. In this method, samples were injected using a large-volume direct injection technique, the analyte anions were separated on a hydroxide-selective anion-exchange column using high-purity hydroxide eluents generated by an on-line ...

متن کامل

Perchloroethylene Analysis by Chemical Oxidation and Determination of Intermediate Products by Gas Chromatography, Mass Spectrometry

Abstract Background and Objective: Perchloroethylene (PCE) is a chlorinated hydrocarbon used as a solvent in many industrial processes. In contaminated water and soil a great deal of PCE is found. This study aimed to determine the rate of decomposition of PCE occurred after advanced oxidation. Material and Methods: In this descriptive-analytic study conducted (2011) in public health faculty...

متن کامل

Determination of trace anions in high-nitrate matrices by ion chromatography.

An ion chromatography method was developed to determine trace anionic contamination in matrices that have a high concentration of nitrate ion. Contaminant anions of interest were separated on an IonPac AS15 high-capacity anion-exchange column and detected by suppressed conductivity detection. An EG40 eluent generator was used to prepare high-purity and carbonate-free potassium hydroxide. Using ...

متن کامل

Determination of Zoledronic Acid and Four Common Anions in Zoledronic Acid Injection by Gradient Ion Chromatography with a Self-Regeneration Suppressor

A simple method to determine zoledronic acid and impurities in drug by ion chromatography with conductivity detection was developed. Target analytes have been sufficiently separated from each other on an Ionpac AS19 by using potassium hydroxide as eluent with a self-regeneration suppressor. This novel proposed method enables direct analysis of zoledronic acid in injection sample and provides go...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999