Tapered modular fluted titanium stems for femoral fixation in revision total knee arthroplasty

نویسندگان

  • Jeffrey B. Stambough
  • J. Bohannon Mason
  • Aldo M. Riesgo
  • Thomas K. Fehring
چکیده

Consensus regarding femoral stem fixation options in revision total knee arthroplasty remains controversial. Tapered, modular, fluted titanium (TMFT) stems have an excellent track record in total hip arthroplasty for their ability to provide axial and rotational stability in situations of compromised host bone. We present 3 successfully treated cases in which the Food & Drug Administration granted permission to use custom TMFT stems in situations of failed femoral fixation in multiple revised knees. These stems hold promise to achieve stable fixation in revision total knee arthroplasty where host metadiaphyseal bone is deficient. Implant manufactures should consider dedicating future resources to create adapters that can link existing successful TMFT stems currently used in hip arthroplasty to revision total knee components when host bone is severely compromised.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modular tapered titanium stems in revision arthroplasty of the hip: The Risk and Causes of Stem Fracture.

Tapered fluted titanium stems are increasingly used for femoral revision arthroplasty. They are available in modular and non-modular forms. Modularity has advantages when the bone loss is severe, the proximal femur is mis shapen or the surgeon is unfamiliar with the implant, but it introduces the risk of fracture of the stem at the junction between it and the proximal body segment. For that rea...

متن کامل

Elevated Serum Titanium Level as a Marker for Failure in a Titanium Modular Fluted Tapered Stem.

Serum ion concentrations of cobalt and chromium are commonly used to monitor for the development of local metal reactions in metal-on-metal total hip arthroplasties, as well as dual-modular constructs. Although rarely used in clinical practice, elevated serum titanium levels have the ability to indicate a failure with contemporary revision constructs, such as with titanium modular fluted tapere...

متن کامل

Managing femoral bone loss in revision total hip replacement: fluted tapered modular stems.

If a surgeon is faced with altered lesser trochanter anatomy when revising the femoral component in revision total hip replacement, a peri-prosthetic fracture, or Paprosky type IIIb or type IV femoral bone loss, a modular tapered stem offers the advantages of accurately controlling femoral version and length. The splines of the taper allow rotational control, and improve the fit in femoral cana...

متن کامل

Tapered fluted modular titanium stems in the management of Vancouver B2 and B3 peri-prosthetic fractures.

Tapered, fluted, modular, titanium stems are increasingly popular in the operative management of Vancouver B2 and selected B3 peri-prosthetic femoral fractures. We have reviewed the results at our institution looking at stem survival and clinical outcomes and compared this with reported outcomes in the literature. Stem survival at a mean of 54 months was 96% in our series and 97% for combined p...

متن کامل

Uncemented femoral revision arthroplasty using a modular tapered, fluted titanium stem

BACKGROUND AND PURPOSE Due to the relative lack of reports on the medium- to long-term clinical and radiographic results of modular femoral cementless revision, we conducted this study to evaluate the medium- to long-term results of uncemented femoral stem revisions using the modular MRP-TITAN stem with distal diaphyseal fixation in a consecutive patient series. PATIENTS AND METHODS We retros...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2018