Detection of airborne Stachybotrys chartarum macrocyclic trichothecene mycotoxins in the indoor environment.
نویسندگان
چکیده
The existence of airborne mycotoxins in mold-contaminated buildings has long been hypothesized to be a potential occupant health risk. However, little work has been done to demonstrate the presence of these compounds in such environments. The presence of airborne macrocyclic trichothecene mycotoxins in indoor environments with known Stachybotrys chartarum contamination was therefore investigated. In seven buildings, air was collected using a high-volume liquid impaction bioaerosol sampler (SpinCon PAS 450-10) under static or disturbed conditions. An additional building was sampled using an Andersen GPS-1 PUF sampler modified to separate and collect particulates smaller than conidia. Four control buildings (i.e., no detectable S. chartarum growth or history of water damage) and outdoor air were also tested. Samples were analyzed using a macrocyclic trichothecene-specific enzyme-linked immunosorbent assay (ELISA). ELISA specificity was tested using phosphate-buffered saline extracts of the fungal genera Aspergillus, Chaetomium, Cladosporium, Fusarium, Memnoniella, Penicillium, Rhizopus, and Trichoderma, five Stachybotrys strains, and the indoor air allergens Can f 1, Der p 1, and Fel d 1. For test buildings, the results showed that detectable toxin concentrations increased with the sampling time and short periods of air disturbance. Trichothecene values ranged from <10 to >1,300 pg/m3 of sampled air. The control environments demonstrated statistically significantly (P < 0.001) lower levels of airborne trichothecenes. ELISA specificity experiments demonstrated a high specificity for the trichothecene-producing strain of S. chartarum. Our data indicate that airborne macrocyclic trichothecenes can exist in Stachybotrys-contaminated buildings, and this should be taken into consideration in future indoor air quality investigations.
منابع مشابه
Detection of trichothecene mycotoxins in sera from individuals exposed to Stachybotrys chartarum in indoor environments.
To date, no study has effectively demonstrated a direct human exposure to mycotoxins in mold-contaminated buildings. Therefore, the authors investigated the presence of trichothecene mycotoxins in sera from individuals exposed to indoor molds (specifically Stachybotrys chartarum). Sera from occupants of contaminated (test samples, n=44) and uncontaminated (control samples, n=26) buildings were ...
متن کاملDetection of airborne Stachybotrys chartarum macrocyclic trichothecene mycotoxins on particulates smaller than conidia.
Highly respirable particles (diameter, <1 microm) constitute the majority of particulate matter found in indoor air. It is hypothesized that these particles serve as carriers for toxic compounds, specifically the compounds produced by molds in water-damaged buildings. The presence of airborne Stachybotrys chartarum trichothecene mycotoxins on particles smaller than conidia (e.g., fungal fragmen...
متن کاملMass spectrometry-based strategy for direct detection and quantification of some mycotoxins produced by Stachybotrys and Aspergillus spp. in indoor environments.
Dampness in buildings has been linked to adverse health effects, but the specific causative agents are unknown. Mycotoxins are secondary metabolites produced by molds and toxic to higher vertebrates. In this study, mass spectrometry was used to demonstrate the presence of mycotoxins predominantly produced by Aspergillus spp. and Stachybotrys spp. in buildings with either ongoing dampness or a h...
متن کاملAirborne Mycotoxin Sampling and Screening Analysis
The indoor mycotoxins inhalation exposure of patients (n=25) was studied using a highvolume air sampler (60 cfm x 24 h) with a micropore-paper filter (8x11 inches). The filters were evaluated for cytotoxicity caused by mycotoxins using the MTT-cell culture bioassay and by culture identification. A subset of samples was analyzed with an enzyme-immuno assay for occurrence of macrocyclic trichothe...
متن کاملStachybotrys chartarum, trichothecene mycotoxins, and damp building-related illness: new insights into a public health enigma.
Damp building-related illnesses (DBRI) include a myriad of respiratory, immunologic, and neurologic symptoms that are sometimes etiologically linked to aberrant indoor growth of the toxic black mold, Stachybotrys chartarum. Although supportive evidence for such linkages is limited, there are exciting new findings about this enigmatic organism relative to its environmental dissemination, novel b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 71 11 شماره
صفحات -
تاریخ انتشار 2005