Selection of neutron-absorbing materials to improve the low-energy response of a Zr-based extended neutron monitor using Monte Carlo simulations.

نویسندگان

  • K Biju
  • C Sunil
  • S P Tripathy
  • D S Joshi
  • T Bandyopadhyay
  • P K Sarkar
چکیده

Monte Carlo simulations have been carried out using the FLUKA code to improve the neutron ambient dose equivalent [H*(10)] response of the ZReC (zirconium-lined portable neutron counter responding satisfactorily to neutrons up to 1 GeV) by introducing various neutron absorbers in the system such as cadmium, gadolinium, natural boron, enriched (10)B and borated polythene. It was found that ZReC can be effectively used as a portable neutron monitor by introducing any one of the following perforated layers: 5 mm thick natural boron, 0.5 mm thick enriched (10)B or 1 cm high-density polythene mixed with 50 % boron by weight. The integral response of the instrument was also calculated for some typical reference neutron fields. The relative ambient dose equivalent response of the said system is also found comparable with that of the existing LINUS neutron monitor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum

Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...

متن کامل

Monte Carlo characterization of photoneutrons in the radiation therapy with high energy photons: a Comparison between simplified and full Monte Carlo models

Background: The characteristics of secondary neutrons in a high energy radiation therapy room were studied using the MCNPX Monte Carlo (MC) code. Materials and Methods: Two MC models including a model with full description of head components and a simplified model used in previous studies were implemented for MC simulations. Results: Results showed 4-53% difference between full and wit...

متن کامل

The study of neutron interactions with soft tissue using Monte Carlo simulation using the source PF

The most important part of neutron therapy treatment (NCT1) is to achieve a beam of neutrons with suitable energy and intensity, as well as the least pollution and damage. In this study, in order to correct the neutron spectrum from D-D fusion and its use in neutron therapy, a set of different materials which are called the Beam Shaping Assembly (BSA) was placed in the direction of energy 2.45 ...

متن کامل

Investigation of Developed Shield Composition to Neutron Shielding in Treatment Room for BNCT to Reduce Clinical Effects

Background and Aim: One of the best radiotherapy methods that have been suggested for the treatment of cancers such as brain, head and neck, skin, and recently liver is boron neutron capture therapy. Therefore, neutron shielding in the treatment room is important because the absorption of neutrons in the shield may lead to the production of gamma rays, which can have destructive effects. While ...

متن کامل

The comparison between simple and advanced shielding materials for the shield of portable neutron sources

Background: Monte Carlo simulations play a vital role in the calculation of the necessary shielding both for neutrons and photons. Advanced and simple shielding materials against neutron and gamma rays were compared by simulation using the MCNB4B Monte Carlo code. The simulations were carried out for the three common neutron sources, namely the 252Cf, the 241Am/Be and the DD neutron generator w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 163 2  شماره 

صفحات  -

تاریخ انتشار 2015