Balloon dilatation of porcine bioprosthetic valves in the pulmonary position.
نویسندگان
چکیده
Balloon dilatation (BD) of bioprosthetic valves was investigated in vivo and in vitro. Four children with stenotic bioprosthetic porcine valves in the pulmonary position underwent BD of the valve 10 to 24 months after its insertion. Average valve gradient was reduced from 47.5 to 27 mm Hg. Obstruction at the conduit-branch pulmonary artery connection became apparent after dilatation of the valve. These distal stenoses were also dilated. BD technique was tested in vitro with the use of nonstenotic valves in fresh conduits. No damage to the valve or to the conduit was found when oversized balloons were used in a standard fashion or intentionally inflated until rupture. It is concluded that conduit replacement may be deferred by balloon dilatation of obstructed biological valves and/or a stenotic conduit-pulmonary artery anastomosis.
منابع مشابه
Diagnosis.
Balloon dilatation (BD) of bioprosthetic valves was investigated in vivo and in vitro. Four children with stenotic bioprosthetic porcine valves in the pulmonary position underwentBD of the valve 10 to 24 months after its insertion. Average valve gradient was reduced from 47.5 to 27 mm Hg. Obstruction at the conduit-branch pulmonary artery connection became apparent after dilatation of the valve...
متن کاملDetection of deterioration or infection of homograft and porcine xenograft bioprosthetic valves in mitral and aortic positions by two-dimensional echocardiographic examination.
Results of two-dimensional echocardiographic examinations were compared with angiographic, hemodynamic and surgical results in 44 patients with bioprosthetic valves in mitral and aortic positions who were undergoing elective or urgent reinvestigation 24 to 87 months (mean 34) after implantation. In these patients, there were 18 homograft aortic valves in the aortic position, 9 stent-mounted hom...
متن کاملFrequency of the first heart sound in the assessment of stiffening of mitral bioprosthetic valves.
The frequency spectrum of the first heart sound (S1) was measured noninvasively in 54 patients with porcine bioprosthetic valves inserted in the mitral position. Phonocardiograms were recorded on magnetic tape on line with a signal processor with which the frequency spectrum and peak frequency of S1 were determined. In 19 patients with normal natural mitral valves, the apparent peak frequency w...
متن کاملNon-invasive assessment by Doppler ultrasound of 155 patients with bioprosthetic valves: a comparison of the Wessex porcine, low profile Ionescu-Shiley, and Hancock pericardial bioprostheses.
One hundred and fifty five patients with 167 bioprosthetic valves (68 Wessex porcine, 54 Hancock pericardial, and 45 low profile Ionescu-Shiley pericardial valves) were studied by Doppler ultrasound. Valve gradients were calculated from the mitral and aortic flow velocities by the modified Bernoulli equation. Mean mitral gradients were significantly smaller across the Ionescu-Shiley valves than...
متن کاملTrans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)
Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 76 1 شماره
صفحات -
تاریخ انتشار 1987