When is it safe to manually lift a patient?

نویسنده

  • Thomas R Waters
چکیده

In 1994 the National Institute for Occupational Safety and Health (NIOSH) released the Revised NIOSH Lifting Equation-an ergonomics assessment tool that can be used to calculate the recommended weight limit for two-handed manual-lifting tasks. However, NIOSH excluded assessment of patient-handling tasks from the uses of the revised equation, arguing that such tasks involve too many variables. The equation in fact can be used to calculate a recommended weight limit for a limited range of patient-handling tasks in which the patient is cooperative and unlikely to move suddenly during the task. In general, the revised equation yields a recommended 35-lb. maximum weight limit for use in patient-handling tasks. When weight to be lifted exceeds this limit, assistive devices should be used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی سنسیتومتریک فیلم‌های رادیوگرافی دندانی F, E در دو سیستم ظهور و ثبوت دستی و اتوماتیک

Background and Aim: Processing conditions affect sensitometric properties of X-ray films. In this study, we aimed to evaluate the sensitometric characteristics of InSight (IP), a new F-speed film, in fresh and used processing solutions in dental office condition and compare them with Ektaspeed Plus (EP).Materials and Methods: In this experimental in vitro study, an aluminium step wedge was used...

متن کامل

Using Absorbable Gelatin Sponge to Facilitate Sinus Membrane Elevation during Open Sinus Lift: Technical Notes and Case Series

Ridge atrophy accompanied by the pneumatization of maxillary sinus in the maxillary posterior region may lead to inadequate bone height, thereby precluding implant placement. Therefore, it may be mandatory to perform a sinus membrane elevation procedure and augmentation in the bone. The present study aimed to introduce a novel modification method for sinus floor elevation using a gelatin sponge...

متن کامل

Comparison of Lift and Drag Forces for Some Conical Bodies in Supersonic Flow Using Perturbation Techniques

Numerical methods are not always convergent especially in higher velocities when shock waves are involved. A comparison analysis is performed to study the supersonic flow over conical bodies of three different cross sections circular, elliptic and squircle (square with rounded corners) shaped using  Perturbation techniques to find flow variables analytically. In order to find lift and drag forc...

متن کامل

Determining Changes in Electromyography Indices when Measuring Maximum Acceptable Weight of Lift in Iranian Male Students

Background: In spite of the increasing degree of automation in industry, manual material handling (MMH) is still performed in many occupational settings. The aim of the current study was to determine the maximum acceptable weight of lift using psychophysical and electromyography indices.Methods: This experimental study was conducted among 15 male students recruited from Tehran University of Med...

متن کامل

When Can We Lift the Coronavirus Pandemic Restrictions? Not Before Taking These Steps

When Can We Lift the Coronavirus Pandemic Restrictions? Not Before Taking These Steps. The American Enterprise Institute, a public policy think tank, recently released a report co-written by former U.S. Food and Drug Administration commissioner Scott Gottlieb that offers a four-phase “road map to reopening.” The first phase involves slowing the spread of new infections with physical distancing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of nursing

دوره 107 8  شماره 

صفحات  -

تاریخ انتشار 2007