Microbiological tests were carried out to evaluate a new chlorine dioxide sterilant: Tristel OneShot. Preliminary in vitro suspension tests showed that solutions containing around 140 ppm chlorine dioxide achieved a reduction factor exceeding 10(6) of Staphylococcus aureus in 1min and of Bacillus subtilis spores in 2.5 min in the presence of 3g/L bovine albumin. Subsequent tests evaluated the effectiveness of Tristel One-Shot in a Medivator washer/disinfector fitted with a Tristel Generator for processing flexible endoscopes. Each test run involved three stages. In the first, the instrument and air-water channels of a gastroscope were inoculated with a suspension of Pseudomonas aeruginosa (10(8)cfu/ml) in 10% sodium glutamate and serum (0, 5 or 10%) and then drained, partially dried, and saline flushed through for total viable counts (TVCs). In the second stage, the channels were re-inoculated with test organisms; detergent was flushed through the channels which were then brushed; and saline was flushed through for TVCs. In the third stage, the channels were re-inoculated; detergent was flushed through the channels which were then brushed; the endoscope was processed in the Medivator; and saline was flushed through for TVCs. Carrying out all three stages enabled determination of (1) the contribution played by manual cleaning of channels prior to processing in the Medivator, and (2) the combined effect of manual cleaning followed by processing. Two series of test runs were done. In the first, the Tristel Generator was set to generate 230ppm chlorine dioxide, and in the second 150ppm. In the first, cleaning followed by processing in the Medivator consistently achieved a >/= 10(6)-fold reduction of test organisms, and in the second a >/= 10(5)-fold reduction. Pre-cleaning of channels was very important-when done the initial concentration of serum in the inoculum (0-10%) had no affect on the results obtained after processing.
منابع مشابه
Endoscope disinfection using chlorine dioxide in an automated washer-disinfector.
Although 2% glutaraldehyde is often the first-line agent for endoscopic disinfection, its adverse reactions are common among staff and it is less effective against certain mycobacteria and spore-bearing bacteria. Chlorine dioxide is a possible alternative and an automated washer-disinfector fitted with this agent is currently available. This study was conducted to evaluate the effectiveness of ...
متن کاملGlutaraldehyde-resistant Mycobacterium chelonae from endoscope washer disinfectors.
Glutaraldehyde is used to disinfect flexible and other heat-sensitive endoscopes often with the aid of automated systems. Mycobacterium chelonae is being isolated with increasing frequency from these washer disinfectors and processed endoscopes. This has, on occasions, led to misdiagnosis and iatrogenic infections. Recent reports suggest that disinfecting machines, on a sessional or regular bas...
متن کاملMycobactericidal activity of chlorine dioxide wipes in a modified prEN 14563 test.
Tristel Sporicidal Wipes are chlorine dioxide-based disinfectant wipes for disinfecting non-lumened semi-critical medical devices. In this study, the mycobactericidal activity of this product was assessed by a modified version of the European Standard prEN 14563 carrier test under clean conditions against Mycobacterium avium. The chlorine dioxide concentration in the activated wipe was 200ppm. ...
متن کاملBacillus subtilis vegetative isolate surviving chlorine dioxide exposure: an elusive mechanism of resistance.
AIMS Oxidizing agents such as chlorine dioxide are widely used microbicides, including for disinfection of medical equipment. We isolated a Bacillus subtilis isolate from a washer-disinfector whose vegetative form demonstrated unique resistance to chlorine dioxide (0·03%) and hydrogen peroxide (7·5%). The aim of this study was to understand the mechanisms of resistance expressed by this isolate...
متن کاملLow-temperature decontamination with hydrogen peroxide or chlorine dioxide for space applications.
The currently used microbial decontamination method for spacecraft and components uses dry-heat microbial reduction at temperatures of >110°C for extended periods to prevent the contamination of extraplanetary destinations. This process is effective and reproducible, but it is also long and costly and precludes the use of heat-labile materials. The need for an alternative to dry-heat microbial ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of hospital infection
دوره 48 1 شماره
صفحات -