Active versus passive cooling during work in warm environments while wearing firefighting protective clothing.

نویسندگان

  • G A Selkirk
  • T M McLellan
  • J Wong
چکیده

This study examined whether active or passive cooling during intermittent work reduced the heat strain associated with wearing firefighting protective clothing (FPC) and self-contained breathing apparatus (SCBA) in the heat (35 degrees Celsius, 50% relative humidity). Fifteen male Toronto firefighters participated in the heat-stress trials. Subjects walked at 4.5 km.h(-1) with 0% elevation on an intermittent work (50 min) and rest (30 min) schedule. Work continued until rectal temperature (T(re)) reached 39.5 degrees Celsius, or heart rate (HR) reached 95% of maximum or exhaustion. One of three cooling strategies, forearm submersion (FS), mister (M), and passive cooling (PC) were employed during the rest phases. Tolerance time (TT) and total work time (WT) (min) were significantly increased during FS (178.7 +/- 13.0 and 124.7 +/- 7.94, respectively) and M (139.1 +/- 8.28 and 95.1 +/- 4.96, respectively), compared with PC (108.0 +/- 3.59 and 78.0 +/- 3.59). Furthermore, TT and WT were significantly greater in FS compared with M. Rates of T(re) increase, HR and T-(sk) were significantly lower during active compared with passive cooling. In addition, HR and T(re) values in FS were significantly lower compared with M after the first rest phase. During the first rest phase, T(re) dropped significantly during FS (approximately 0.4 degree Celsius) compared with M (approximately 0.08 degree Celsius) while PC increased (approximately 0.2 degree Celsius). By the end of the second rest period T(re) was 0.9 degree Celsius lower in FS compared with M. The current findings suggest that there is a definite advantage when utilizing forearm submersion compared with other methods of active or passive cooling while wearing FPC and SCBA in the heat.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The management of heat stress for the firefighter: a review of work conducted on behalf of the Toronto Fire Service.

This report provides a summary of research conducted through a grant provided by the Workplace Safety Insurance Board of Ontario. The research was divided into two phases; first, to define safe work limits for firefighters wearing their protective clothing and working in warm environments; and, the second, to examine strategies to reduce the thermal burden and extend the operational effectivene...

متن کامل

Heat stress while wearing long pants or shorts under firefighting protective clothing.

It was the purpose of this study to examine whether replacing long pants (P) with shorts (S) would reduce the heat stress of wearing firefighting protective clothing during exercise in a warm environment. Twenty-four Toronto Firefighters were allocated to one of four groups that performed heavy (H, 4.8 km x h(-1), 5% grade), moderate (M, 4.5 km x h(-1), 2.5% grade), light (L, 4.5 km x h(-1)) or...

متن کامل

Protective clothing ensembles and physical employment standards1

Physical employment standards (PESs) exist for certain occupational groups that also require the use of protective clothing ensembles (PCEs) during their normal work. This review addresses whether these current PESs appropriately incorporate the physiological burden associated with wearing PCEs during respective tasks. Metabolic heat production increases because of wearing PCE; this increase is...

متن کامل

Efficfncy of Combinations of Cooling for Microclimate Cooling Suit Design, Tested in Man at 100°f with Exercise

A recent concern in hazardous materials containment, removal, and military operations has been the heat and work stress imposed on personnel wearing chemical and biological protective clothing (Chemical and Biological Protection Suit, Carbon Sphere #8415-01-333-7578 and gas maskkowl, MSA91J012-013; CBR). Several microclimate-cooling systems have been tested as possible solutions (1). Although t...

متن کامل

Effect of base layer materials on physiological and perceptual responses to exercise in personal protective equipment.

Ten men (non-firefighters) completed a 110 min walking/recovery protocol (three 20-min exercise bouts, with recovery periods of 10, 20, and 20 min following successive bouts) in a thermoneutral laboratory while wearing firefighting personal protective equipment over one of four base layers: cotton, modacrylic, wool, and phase change material. There were no significant differences in changes in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of occupational and environmental hygiene

دوره 1 8  شماره 

صفحات  -

تاریخ انتشار 2004