We placed negative electrodes on the body and positive electrodes at the medial and lateral canthi, measured their potentials separately, evaluated their characteristics, and analyzed cross-talk. We recorded EOG in 6 normal subjects and found the following. The potential at the medial was lower than that at the lateral canthus in the bilateral eyes. The polarity of waves at the lateral was reverse to that at the medial canthus in the bilateral eyes. We recorded EOG in 6 patients with unilateral anophthalmia and found the following. On the anophthalmia side, the potential at the lateral was considerably lower than that at the medial canthus. The polarity of the potential was the same between the medial and lateral canthi. The mean cross-talk to the medial canthus on the anophthalmia side was 8.7%-54.0% of the potential at the medial canthus on the normal side. The mean cross-talk to the lateral canthus on the anophthalmia side was 4.4%-16.9%. The influence of cross-talk of the other eye was marked at the medial but slight at the lateral canthus. In EOG recording, results with minimum errors due to cross-talk can be obtained by paying attention to the potential at the lateral canthus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface Modification of Glassy Carbon Electrode by Ni-Cu Nanoparticles as a Competitive Electrode for Ethanol Electro-Oxidation

In the present study, Nickel-Copper nanoparticles were electrodeposited on glassy carbon electrode (GCE) by using electroplating deposition method. The prepared electrode was characterized by scanning electron microscopy (SEM) and elemental mapping analysis. Results showed that Ni-Cu nanoparticles with a high density are distributed at the surface of the glassy carbon electrode. Subsequentl...

متن کامل

Detection of Ascorbic Acid in Biological Samples by a New Modified Glassy Carbon Electrode

The present work describes the construction of a new modified electrode by casting the appropriate mixture of a metallocene, which has been introduced in the experimental part, as a mediator at the surface of glassy carbon (GC) electrode. The proposed modified GC electrode was used for the determination of ascorbic acid (AA) in phosphate buffer (PB) solution (pH = 4.0). When compared to bare GC...

متن کامل

Application of copper oxide nanoparticles modified glassy carbon electrode for electrocatalytic oxidation of methanol

Copper nanoparticles were fabricated by electro-reduction of CuSO4solution in the presence of cetyltrimethylammonium bromide (CTAB) cationic surfactant as an additive through potentiostatic method. The prepared copper nanoparticles were characterized by scanning electron microscopy (SEM) and electrochemical methods. The SEM images reveal that the nanoparticles with diameters at about 70 n...

متن کامل

Application of Iron Electrode in Textile Industry Wastewater Treatment Using Electro-fenton Technique: Experimental and Statistical Study

The application of synthetic colors in textile industries and their entry into the water and groundwater is an environmental problem because of being very toxic material. The synthetic colors which are used in textile dyeing (plyacrilic and polyester) are usually dispersing colorants. They derive the azo and anthraquinone chemicals. Electro-Fenton process is an efficient technique which can deg...

متن کامل

Study and Electrochemical Determination of Tyrosine at Graphene Nanosheets Composite Film Modified Glassy Carbon Electrode

A graphene nanosheets (GNS) film coated glassy carbon electrode (GCE) was fabricated for sensitive determination of tyrosine (Tyr). The GNS-based sensor was characterized by scanning electron microscope and electrochemical impedance spectroscopy. The voltammetric techniques were employed to study electro-oxidation of Tyr. The results revealed that the modified electrode showed an electrocatalyt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of medical investigation : JMI

دوره 55 1-2  شماره 

صفحات  -

تاریخ انتشار 2008