Contrast-enhanced anatomic imaging as compared to contrast-enhanced tissue characterization for detection of left ventricular thrombus.
نویسندگان
چکیده
OBJECTIVES This study sought to compare contrast-enhanced anatomic imaging and contrast-enhanced tissue characterization (delayed-enhancement cardiac magnetic resonance [DE-CMR]) for left ventricular (LV) thrombus detection. BACKGROUND Contrast echocardiography (echo) detects LV thrombus based on anatomic appearance, whereas DE-CMR imaging detects thrombus based on tissue characteristics. Although DE-CMR has been validated as an accurate technique for thrombus, its utility compared with contrast echo is unknown. METHODS Multimodality imaging was performed in 121 patients at high risk for thrombus due to myocardial infarction or heart failure. Imaging included 3 anatomic imaging techniques for thrombus detection (contrast echo, noncontrast echo, cine-CMR) and a reference of DE-CMR tissue characterization. LV structural parameters were quantified to identify markers for thrombus and predictors of additive utility of contrast-enhanced thrombus imaging. RESULTS Twenty-four patients had thrombus by DE-CMR. Patients with thrombus had larger infarcts (by DE-CMR), more aneurysms, and lower LV ejection fraction (by CMR and echo) than those without thrombus. Contrast echo nearly doubled sensitivity (61% vs. 33%, p < 0.05) and yielded improved accuracy (92% vs. 82%, p < 0.01) versus noncontrast echo. Patients who derived incremental diagnostic utility from DE-CMR had lower LV ejection fraction versus those in whom noncontrast echo alone accurately assessed thrombus (35 +/- 9% vs. 42 +/- 14%, p < 0.01), with a similar trend for patients who derived incremental benefit from contrast echo (p = 0.08). Contrast echo and cine-CMR closely agreed on the diagnosis of thrombus (kappa = 0.79, p < 0.001). Thrombus prevalence was lower by contrast echo than DE-CMR (p < 0.05). Thrombus detected by DE-CMR but not by contrast echo was more likely to be mural in shape or, when apical, small in volume (p < 0.05). CONCLUSIONS Echo contrast in high-risk patients markedly improves detection of LV thrombus, but does not detect a substantial number of thrombi identified by DE-CMR tissue characterization. Thrombi detected by DE-CMR but not by contrast echo are typically mural in shape or small in volume.
منابع مشابه
Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates
Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...
متن کاملFDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT
Objective(s): In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT), complicating hepatocellular carcinoma (HCC) in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT), which is a comb...
متن کاملQuantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging
Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...
متن کاملAutomatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI
Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...
متن کاملEffect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular imaging
دوره 2 8 شماره
صفحات -
تاریخ انتشار 2009