Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery.
نویسندگان
چکیده
BACKGROUND Continuous non-invasive measurement of finger arterial pressure (FAP) is a reliable technology in adults. FAP is measured with an inflatable cuff around the finger and simultaneously converted to a reconstructed brachial artery pressure waveform (reBAP) by the Nexfin™ device. We assessed the adequacy of a prototype device (Nexfin-paediatric), designed for a paediatric population, for detecting rapid arterial pressure changes in children during cardiac surgery. METHODS Thirteen anaesthetized children with a median age of 11 months (2 months-7 yr) undergoing congenital cardiac surgery were included in the study. reBAP and intra-arterial pressure (IAP) were recorded simultaneously during the surgical procedure. To assess the accuracy of reBAP in tracking arterial pressure changes, the four largest IAP variations within a 5 min time interval were identified from each procedure. These variations were compared offline with reBAP during a 10 s control period before and a 10 s period after an arterial pressure change had occurred. RESULTS In 10 out of 13 children, a non-invasive arterial pressure recording could be obtained. Therefore, recordings from these 10 children were eligible for further analysis, resulting in 40 data points. The correlation coefficient between reBAP and IAP in tracking mean arterial pressure (MAP) changes was 0.98. reBAP followed changes in IAP with a mean bias for systolic, diastolic arterial pressure, and MAP of 0.0 mm Hg (sd 5.8), 0.1 (sd 2.8), and 0.19 (sd 2.7), respectively. CONCLUSIONS The prototype device closely follows arterial pressure changes in children. However, in a considerable number of attempts, obtaining a signal was time-consuming or unsuccessful. This technique seems promising but requires further technical development.
منابع مشابه
Level of agreement between Nexfin non-invasive arterial pressure with invasive arterial pressure measurements in children.
BACKGROUND We compared Nexfin non-invasive arterial pressure measurements using a novel small finger cuff with intra-arterial pressure in the paediatric setting in order to establish the level of agreement between both methods. METHODS The study included 41 children aged 2-16 yr admitted for surgery or paediatric intensive care with an intra-arterial catheter as part of standard monitoring. V...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملNon-invasive continuous blood pressure monitoring of tachycardic episodes during interventional electrophysiology
AIMS We thought to evaluate feasibility of continuous non-invasive blood pressure monitoring during procedures of interventional electrophysiology. METHODS AND RESULTS We evaluated continuous non-invasive finger blood pressure (BP) monitoring by means of the Nexfin device in 22 patients (mean age 70 ± 24 years), undergoing procedures of interventional electrophysiology, in critical situations...
متن کاملComparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملComparison of continuous non-invasive finger arterial pressure monitoring with conventional intermittent automated arm arterial pressure measurement in patients under general anaesthesia.
BACKGROUND For a majority of patients undergoing anaesthesia for general surgery, mean arterial pressure (MAP) is only measured intermittently by arm cuff oscillometry (MAPiNIAP). In contrast, the Nexfin(®) device provides continuous non-invasive measurement of MAP (MAPcNIAP) using a finger cuff. We explored the agreement of MAPcNIAP and MAPiNIAP with the gold standard: continuous invasive MAP ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 105 4 شماره
صفحات -
تاریخ انتشار 2010