Assessment of stereoscopic optic disc images using an autostereoscopic screen – experimental study
نویسندگان
چکیده
BACKGROUND Stereoscopic assessment of the optic disc morphology is an important part of the care of patients with glaucoma. The aim of this study was to assess stereoviewing of stereoscopic optic disc images using an example of the new technology of autostereoscopic screens compared to the liquid shutter goggles. METHODS Independent assessment of glaucomatous disc characteristics and measurement of optic disc and cup parameters whilst using either an autostereoscopic screen or liquid crystal shutter goggles synchronized with a view switching display. The main outcome measures were inter-modality agreements between the two used modalities as evaluated by the weighted kappa test and Bland Altman plots. RESULTS Inter-modality agreement for measuring optic disc parameters was good [Average kappa coefficient for vertical Cup/Disc ratio was 0.78 (95% CI 0.62-0.91) and 0.81 (95% CI 0.6-0.92) for observer 1 and 2 respectively]. Agreement between modalities for assessing optic disc characteristics for glaucoma on a five-point scale was very good with a kappa value of 0.97. CONCLUSION This study compared two different methods of stereo viewing. The results of assessment of the different optic disc and cup parameters were comparable using an example of the newly developing autostereoscopic display technologies as compared to the shutter goggles system used. The Inter-modality agreement was high. This new technology carries potential clinical usability benefits in different areas of ophthalmic practice.
منابع مشابه
Deposited in DRO : 29
Background: Stereoscopic assessment of the optic disc morphology is an important part of the care of patients with glaucoma. The aim of this study was to assess stereoviewing of stereoscopic optic disc images using an example of the new technology of autostereoscopic screens compared to the liquid shutter goggles. Methods: Independent assessment of glaucomatous disc characteristics and measurem...
متن کاملDigital imaging of the optic nerve head: monoscopic and stereoscopic analysis.
AIMS To compare monoscopic and stereoscopic assessment of the optic disc using novel software for the digital stereoscopic analysis of optic disc stereopairs. METHODS Software was developed for the stereoscopic display of digital optic disc images using an interlaced display method. Neuroretinal rim width was determined at 10 degree intervals around the optic disc using a custom (stereoscopic...
متن کاملSoftware-Assisted Depth Analysis of Optic Nerve Stereoscopic Images in Telemedicine
Background. Software guided optic nerve assessment can assist in process automation and reduce interobserver disagreement. We tested depth analysis software (DAS) in assessing optic nerve cup-to-disc ratio (VCD) from stereoscopic optic nerve images (SONI) of normal eyes. Methods. In a prospective study, simultaneous SONI from normal subjects were collected during telemedicine screenings using a...
متن کاملAssessment of optic disc photographs for glaucoma by UK optometrists: the Moorfields Optic Disc Assessment Study (MODAS).
PURPOSE To assess the ability of UK optometrists to accurately discriminate between stereoscopic photographs of healthy and glaucomatous optic discs. METHODS An online survey, including questions relating to qualification, practice environment, and diagnostic methods was completed by 1256 optometrists. Based on their responses, 208 (17%) were selected to undertake an online disc assessment ex...
متن کاملAutomatic Optic Disc Center and Boundary Detection in Color Fundus Images
Accurately detection of retinal landmarks, like optic disc, is an important step in the computer aided diagnosis frameworks. This paper presents an efficient method for automatic detection of the optic disc’s center and estimating its boundary. The center and initial diameter of optic disc are estimated by employing an ANN classifier. The ANN classifier employs visual features of vessels and th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMC Ophthalmology
دوره 8 شماره
صفحات -
تاریخ انتشار 2008