Heparin-coated Wiktor stents in human coronary arteries (MENTOR trial). MENTOR Trial Investigators.
نویسندگان
چکیده
The purpose of this study was to determine the feasibility, safety, and efficacy of elective stenting with heparin-coated Wiktor stents in patients with coronary artery disease. In experimental studies, heparin coating has been shown to prevent subacute thrombosis and restenosis. Recently, a new method of heparin coating was developed, resulting in a more stable and predictable heparin layer on stent devices. This trial constitutes the first in-human use of this coating procedure, applied on the well-known Wiktor stent device. Heparin-coated Wiktor stent implantation was performed in 132 consecutive patients (132 lesions) in a multicenter international trial from September 1996 to February 1997. Forty-three percent of patients had unstable angina, 33% had previous myocardial infarction, and 10% had diabetes mellitus. Patients were followed for 12 months for occurrence of major adverse cardiovascular events, and 96% of the eligible patients underwent quantitative angiographic control at 6 months. Stent deployment was successful in 95.5% of lesions. Minimal lumen diameter increased by 1.67 +/- 0.48 mm (from 1.02 +/- 0.38 mm before to 2.69 +/- 0.37 mm after the stent implantation). Mean percent diameter stenosis decreased from 67.4 +/- 11.3% before to 18.9 +/- 7.7% after the intervention. A successful intervention (<50% diameter stenosis and no major adverse cardiac events within 30 days) occurred in 97% of the patients. The subacute thrombosis rate was 0.8%, which compares favorably with historical controls of this stent, and a low incidence of postprocedural increase in creatine kinase-MB was noted. At 6 months, event-free survival was 85% and angiographic restenosis rate was 22% with late loss of 0.78 +/- 0.69 mm and a loss index of 0.48 +/- 0.44. Heparin-coated Wiktor stents appeared to be an efficacious device to treat Benestent-like lesions, yielding angiographic and clinical results comparable to a heparin-coated Palmaz-Schatz stent. Despite its use in more complex lesions, the incidence of subacute thrombosis appeared to be lower than historical controls with a similar noncoated stent.
منابع مشابه
Heparin-coated stent placement for the treatment of stenoses in small coronary arteries of symptomatic patients.
BACKGROUND The role of stents, especially of heparin-coated stents for the treatment of stenoses in small coronary arteries, is still unclear. Therefore, we performed this prospective, randomized trial to evaluate the angiographic and clinical outcome after treatment of stenoses in small coronary arteries (2.0 to 2.6 mm) of symptomatic patients. METHODS AND RESULTS We randomly assigned 588 pa...
متن کاملDetermining prognosis early after a myocardial infarction.
[1] Serruys PW, de Jaegere P, Kiemeneij F et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. N Engl J Med 1994; 331: 489–95. [2] Topol EJ, Leya F, Pinkerton CA et al. A comparison of directional atherectomy with coronary angioplasty in patients with coronary artery disease. The CAVEAT Study Group...
متن کاملEffect of Heparin Administration during Coronary Angiography on Vascular or Peripheral Complications: A Single-Blind Randomized Controlled Clinical Trial
Background: Coronary angiography consists of the selective injection of contrast agents in coronary arteries. Optimal strategy for heparin administration during coronary angiography has yet to be determined. We assessed the effect of heparin administration during coronary angiography on vascular, hemorrhagic, and ischemic complications.Methods: Five hundred candiates for diagnostic coronary ang...
متن کاملStenting in small coronary arteries (SISCA) trial. A randomized comparison between balloon angioplasty and the heparin-coated beStent.
OBJECTIVES The purpose of this study was to assess the clinical and angiographic benefits of elective stenting in coronary arteries with a reference diameter of 2.1 to 3.0 mm, as compared with traditional percutaneous transluminal coronary angioplasty (PTCA). BACKGROUND The problems related to small-vessel stenting might be overcome using modern stents designed for small vessels, combined wit...
متن کاملCRT 2017 late-breaking trials.
1. Impact of technique on early and late outcomes following coronary Bioresorbable scaffold implantation: Analysis from the ABSORB trials . . . . . 304 2. Two-year clinical outcomes of the ABSORB BVS compared EES: A propensity matched analysis of the BVS expand registry . . . . . . . . . . . . 305 3. Transcatheter aortic valve replacement using the Lotus valve with Depth Guard: First report fro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of cardiology
دوره 86 4 شماره
صفحات -
تاریخ انتشار 2000