Supralinearity of Peak 5 and Peak 6 in TLD-700
نویسندگان
چکیده
Track theory has been applied to an earlier suggestion, that the supralinearity of TLDs at high gamma-ray doses is due to pre-existing 1-hit and 2-hit trap structures, to calculate high-LET response. Measured 60Co dose responses for peaks 5 and 6 in LiF (TLD700) were decomposed to yield parameters characterizing each peak as a two-component c-hit mixture. One value of “trap radius” was assigned to each two-component representation, different for peak 5 and for peak 6, to calculate their responses for H, He, C, O, and Ne bombardments. Calculations reproduce experimental features of the heavy ion response of TLD-700, and provide a means of connecting the gammaand high-LET responses, in TLDs.
منابع مشابه
Review of Methods for Determining Glow Peak Kinetics Parameters of Thermoluminescence Dosemeters
In the field of thermoluminescence dosimetry the daily analysis of multi-peak glow curves includes computerized curve-fitting methods, the so-called deconvolutions. These are in need of restricting the kinetic parameters E and s in order to obtain physically relevant results. There have been suggested various methods for the determination of these kinetic parameters based on a theory treating s...
متن کاملتفکیک دز نوترون و گاما در میدانهای آمیختۀ( n-γ (Am-Be, 137Cs) با استفاده از دزیمتر TLD-500
The possibility of employing α-Al2O3:C (TLD-500) for estimation of gamma dose in mixed n-γ radiation fields by two peak method has investigated. It was found that the main peak can be reliably deconvoluted to two component glow peaks. The ratio of peak 2 to peak 1 in pure gamma ray radiation field (137Cs) is 1.49 whereas irradiation by Am-Be neutrons results in a ratio of 1.12. The precision of...
متن کاملتعیین پارامترهای فروکشی دمایی دزیمتر ترمولومینسانس (TLD-100) LiF:Mg,Ti
Thermal quenching is a known and important effect which should be taken into account in studying thermoluminescence (TL) phenomenon. This effect causes the probability of non-radiative recombinations to be increased with raising temperature in TL process. This article deals with changes of the TL glow curve of LiF:Mg, Ti (TLD-100) with heating rate. It was observed that the main dosimetry peak ...
متن کاملGlow-Peak Stability in LiF:Mg,Ti (TLD-600) Exposed to a Fe-ion beam
thermoluminescent detector/LiF:Mg,Ti/glow curve deconvolution/annealing/NIRS-HIMAC The stability of glow peaks in LiF:Mg,Ti (TLD-600) exposed to a high-energy Fe-ion beam was examined in comparison to Cs γ -ray irradiation under changing annealing conditions. The peak areas induced by the Fe ions were much smaller than those by γ -rays. The sizes and positions of peaks 3–5 in Fe-ion irradiated ...
متن کاملGlow-peak stability in 6LiF:Mg,Ti (TLD-600) exposed to a Fe-ion beam.
The stability of glow peaks in 6LiF:Mg,Ti (TLD-600) exposed to a high-energy Fe-ion beam was examined in comparison to 137Cs gamma-ray irradiation under changing annealing conditions. The peak areas induced by the Fe ions were much smaller than those by gamma-rays. The sizes and positions of peaks 3-5 in Fe-ion irradiated samples were hardly changed after post-annealing at 100 degrees C x 30 mi...
متن کامل