Supralinearity of Peak 5 and Peak 6 in TLD-700

نویسندگان

  • Michael P. R. Waligórski
  • Robert Katz
چکیده

Track theory has been applied to an earlier suggestion, that the supralinearity of TLDs at high gamma-ray doses is due to pre-existing 1-hit and 2-hit trap structures, to calculate high-LET response. Measured 60Co dose responses for peaks 5 and 6 in LiF (TLD700) were decomposed to yield parameters characterizing each peak as a two-component c-hit mixture. One value of “trap radius” was assigned to each two-component representation, different for peak 5 and for peak 6, to calculate their responses for H, He, C, O, and Ne bombardments. Calculations reproduce experimental features of the heavy ion response of TLD-700, and provide a means of connecting the gammaand high-LET responses, in TLDs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Review of Methods for Determining Glow Peak Kinetics Parameters of Thermoluminescence Dosemeters

In the field of thermoluminescence dosimetry the daily analysis of multi-peak glow curves includes computerized curve-fitting methods, the so-called deconvolutions. These are in need of restricting the kinetic parameters E and s in order to obtain physically relevant results. There have been suggested various methods for the determination of these kinetic parameters based on a theory treating s...

متن کامل

تفکیک دز نوترون و گاما در میدان‌های آمیختۀ( n-γ (Am-Be, 137Cs) با استفاده از دزیمتر TLD-500

The possibility of employing α-Al2O3:C (TLD-500) for estimation of gamma dose in mixed n-γ radiation fields by two peak method has investigated. It was found that the main peak can be reliably deconvoluted to two component glow peaks. The ratio of peak 2 to peak 1 in pure gamma ray radiation field (137Cs) is 1.49 whereas irradiation by Am-Be neutrons results in a ratio of 1.12. The precision of...

متن کامل

تعیین پارامترهای فروکشی دمایی دزیمتر ترمولومینسانس (TLD-100) LiF:Mg,Ti

Thermal quenching is a known and important effect which should be taken into account in studying thermoluminescence (TL) phenomenon. This effect causes the probability of non-radiative recombinations to be increased with raising temperature in TL process. This article deals with changes of the TL glow curve of LiF:Mg, Ti (TLD-100) with heating rate. It was observed that the main dosimetry peak ...

متن کامل

Glow-Peak Stability in LiF:Mg,Ti (TLD-600) Exposed to a Fe-ion beam

thermoluminescent detector/LiF:Mg,Ti/glow curve deconvolution/annealing/NIRS-HIMAC The stability of glow peaks in LiF:Mg,Ti (TLD-600) exposed to a high-energy Fe-ion beam was examined in comparison to Cs γ -ray irradiation under changing annealing conditions. The peak areas induced by the Fe ions were much smaller than those by γ -rays. The sizes and positions of peaks 3–5 in Fe-ion irradiated ...

متن کامل

Glow-peak stability in 6LiF:Mg,Ti (TLD-600) exposed to a Fe-ion beam.

The stability of glow peaks in 6LiF:Mg,Ti (TLD-600) exposed to a high-energy Fe-ion beam was examined in comparison to 137Cs gamma-ray irradiation under changing annealing conditions. The peak areas induced by the Fe ions were much smaller than those by gamma-rays. The sizes and positions of peaks 3-5 in Fe-ion irradiated samples were hardly changed after post-annealing at 100 degrees C x 30 mi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017