The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis
نویسندگان
چکیده
OBJECTIVES Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. DESIGN AND METHODS 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. RESULTS For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. CONCLUSION The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization.
منابع مشابه
Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.
BACKGROUND Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. METHODS A total of 3...
متن کاملComparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy
INTRODUCTION Urine screening is achieved by either automated or manual microscopic analysis. The aim of the study was to compare Cobas 6500 and Iris IQ200 urine analyzers, and manual urine microscopic analysis. MATERIALS AND METHODS A total of 540 urine samples sent to the laboratory for chemical and sediment analysis were analyzed on Cobas 6500 and Iris IQ200 within 1 hour from sampling. One...
متن کاملHigh False Positives and False Negatives in Yeast Parameter in an Automated Urine Sediment Analyzer
BACKGROUND Automated urine sediment analyzers have proven their feasibility in medical laboratories. However, editing manual microscopic review of some specimens severely limits the usefulness of such systems. This study aims to give feedback on the practical experience on »Yeast«, which is one of the parameters that compel frequent manual reviews. METHODS 5448 freshly collected urine specime...
متن کاملImproving productivity: total urinalysis vs. reflex to microscopy
have shown that omitting microscopy exams results in missed diagnosis, which of course causes repeated specimen collection and additional laboratory testing. A study authored by Nancy Brunzel and Diane Berry analyzing 709 routine specimens revealed reflexing to microscopy resulted in one in four patient samples being overlooked for pathological conditions. The authors reported the negative pred...
متن کاملUrinalysis: The Automated Versus Manual Techniques; Is It Time To Change?.
BACKGROUND Urinalysis is the third major test in clinical laboratory. Manual technique imprecision urges the need for a rapid reliable automated test. We evaluated the H800-FUSIOO automatic urine sediment analyzer and compared it to the manual urinalysis technique to determine if it may be a competitive substitute in laboratories of central hospitals. METHODS 1000 urine samples were examined ...