Decreasing the Commutation Failure Frequency in HVDC Transmission Systems
نویسندگان
چکیده
In this paper we show how a fairly large proportion of those commutation failures that are due to single-phased short circuits to earth can be avoided. In a control circuit based on a digital signal processor (DSP) it is possible, with instantaneous results, to switch from a normal control strategy with equidistant firing pulses to a strategy that takes into consideration the potentially dangerous voltage changes on the supply lines. If the supply voltages are monitored continuously, it is possible to calculate the necessity of advancing the firing pulses to avoid commutation failures. In the paper such a calculation technique is described. The monitoring times may be approximately 50 sec apart corresponding to a distance of 0.016 radians or about 1 .
منابع مشابه
Mitigation of commutation faults in HVDC system
To transfer large amount of direct current power having high amplitude voltage over long distance, high voltage direct current (HVDC) transmission system is used. This system was introduced 60 year ago and now it is widely used all over the world. Some examples of HVDC systems are following; Voltage-SourcedConverter (VSC), current commutated converter (CCC) and line commutated converter (LCC) d...
متن کاملNovel Voltage Source Converter based HVDC Transmission System for Offshore Wind Farms
Offshore wind farms have recently emerged as promising renewable energy sources. For increasing distances between offshore generation and onshore distribution grid, HVDC transmission systems based on voltage source converters can be a feasible and competitive solution. This thesis presents a comprehensive evaluation of a novel integrated wind farm topology that includes the generator drive syst...
متن کاملForced Commutated HVDC Converters
Since the implementation of the first HVDC thyristor valve at Eel River (Canada) in the early 1970’s, HVDC transmission has experienced tremendous growth. As power systems grow and become more integrated, interconnections to neighboring ac systems are becoming increasingly necessary to enhance stability, security of supply, flexibility and for other economic benefits. Primarily for stability re...
متن کاملAnalysis and Improving Reliability Indices of VSC-HVDC transmission system tapped by a VSC- station
During the last three decades, reliability analysis of power systems considering transformers, breakers, transmission lines, and generators failure has been widely applied. This analysis has been done especially in the generation and transmission levels and is mainly restricted to high voltage alternating current (HVAC) systems. HVDC transmission systems are becoming increasingly popular when c...
متن کاملDynamic Harmonic Modeling and Analysis of VSC-HVDC Systems
Harmonics have become an important issue in modern power systems. The widespread penetration of non-linear loads to emerging power systems has turned power quality analysis into an important operation issue under both steady state and transient conditions. This paper employs a Dynamic Harmonic Domain (DHD) based framework for dynamic harmonic analysis of VSC-HVDC systems. These systems are wide...
متن کامل