10-Year experience regarding the reliability and morbidity of radio guided lymph node biopsy in penile cancer patients and the associated radiation exposure of medical staff in this procedure
نویسندگان
چکیده
BACKGROUND The guidelines of the European Association of Urologists (EAU), of the German Society of Nuclear Medicine (DGN), and the European Society for Medical Oncology (ESMO) recommend sentinel lymph node biopsy (SLNB) for lymph node staging in penile cancer with non-palpable inguinal lymph nodes as one diagnostic method. Despite this, the method is neither widely nor regularly applied in Germany - the same applies to many other countries, which may be due to insecurity in dealing with open radioactive tracers. This study aims to assess the reliability and morbidity of this method, as well as the associated radioactive burden for clinical staff. METHODS Between 2006 and 2016, 34 patients with an invasive penile carcinoma and inconspicuous inguinal lymph node status underwent SLNB in 57 groins after application of a radiotracer (Tc-99 m nanocolloid). We collected the results prospectively. The reliability of the method was assessed by determining the false-negative rate. In addition, we evaluated complication rates and determined the radioactive burden for the clinical staff both pre- and intraoperatively. RESULTS SLNB was performed in 34 patients with penile cancer with non-palpable inguinal lymph nodes in 57 groins. In two patients inguinal lymph node metastases were detected by means of SLNB. In one patient recurrent inguinal lymph node disease was found after negative SLNB in both groins. Thus, the false negative rate was 3.13 % per patient (1/32 patients) and 3.51 % per groin (2/57 groins). The morbidity rate was 2.94 % per patient (1/34 patients) and 1.75 % per groin (1/57 groins). Radiation exposure for the clinical staff during this procedure was low at a maximum of ca. four μSV per intervention. CONCLUSIONS SLNB is a reliable method with low morbidity that is associated with a low radiation burden for clinical staff. Due to the enhanced methodological and logistic demands, this intervention should be performed in specialized centres and in an interdisciplinary approach.
منابع مشابه
Sentinel lymph node biopsy in melanoma patients: An experience with Tc-99m antimony sulfide colloid
Introduction: Sentinel lymph node biopsy is the standard procedure for lymph node staging in intermediate thickness melanoma. In Iran, this procedure has not been addressed sufficiently. In this study, we report our experience in this area. Methods: Ten consecutive patients with intermediate thickness melanoma where included in our study. 1.5 mCi of Tc-99m antimony...
متن کاملRadiation exposure of the surgeons in sentinel lymph node biopsy
Background: Sentinel node biopsy (SLNB) is the standard of care for breast cancer treatment and it is getting wide acceptance in Iran. The radiation safety of the procedure has been investigated under controlled conditions, but the standard dose of radiotracer and techniques are not always observed in the community setting. The aim of this study was to assess the magnitude of the absor...
متن کاملThe need for skin pen marking for sentinel lymph node biopsy: A comparative study
Introduction: There is a consensus in the literature that sentinel lymph node biopsy is the standard procedure for axillary staging in early stage (I and II) breast cancer patients. Usually during lymphoscintigraphy, the location of the sentinel lymph node is marked on the skin by an indelible ink. In this study we evaluated this issue in our patients. Methods: 40 ...
متن کاملStandardization of whole breast radiotherapy is required for safe omission of axillary lymph node dissection in breast cancer patients
Background: The purpose of this study was to assess the dose distribution and coverage of level Ⅰ-Ⅱ axillary lymph nodes during whole breast tangential field radiotherapy (RT) after breast-conserving surgery in patients with breast cancer. Materials and Methods: The level Ⅰ-Ⅱ axillary lymph node volumes were retrospectively contoured by a single radiation oncologist based on computed tomography...
متن کاملReliability of radioisotope-guided sentinel lymph node biopsy in penile cancer: verification in consideration of the European guidelines
BACKGROUND Lymph node (LN) staging in penile cancer has strong prognostic implications. This contrasts with the high morbidity of extended inguinal LN dissection (LND) or over-treatment of many patients. Therefore, inguinal dynamic sentinel node biopsy (DSNB) or modified LND is recommended by the European Association of Urology (EAU) guidelines to evaluate the nodal status of patients with clin...
متن کامل