Chromatoprobe as a sample-sparing technique for residual solvent analysis of drug discovery candidates by gas chromatography

نویسندگان

  • Christopher J. Poronsky
  • Jingfang Qian Cutrone
چکیده

In drug discovery research, residual solvent measurement is an integral part of purity analysis for synthesis of a drug candidate before it is used for toxicity testing. This is usually carried out using gas chromatography (GC) with direct injection sample introduction. This method requires testing compounds to be soluble at high concentrations (>50 mg/mL, usually in DMSO) to achieve acceptable sensitivity, a hurdle which is not always achievable for some samples such as cyclic peptides and oligonucleotides. To overcome the limitation associated with the direct injection approach, a new method using the Chromatoprobe thermal extraction device was developed for quantifying residual solvents of drug discovery compounds. This method not only consumes significantly less material (less than 1 mg), but also shows higher sensitivity than the direct injection approach. In addition, because no diluent is required with the Chromatoprobe thermal extraction, all residual solvents can be detected and measured without further method optimization. In our study, we compared data from GC residual solvent analysis using the Chromatoprobe solid sample introduction to those of the direct injection method for seven in-house samples. Our results showed a good agreement between the data from these two sample introduction methods. Thus, the Chromatoprobe sample introduction method provided a sample-sparing alternative to the direct injection method for the measurement of residual solvents in drug discovery. This method can be particularly useful for residual solvent analysis in samples that are available only in limited amounts, poorly soluble, and/or unstable in the diluents used for the direct injection method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Organic Sulfur Contaminants Using Hollow Fibre-protected Liquid-phase Micro-extraction Coupled with Gas Chromatography

A simple and solvent-minimized sample preparation technique based on hollow fibre-protected liquid-phase micro-extraction has been developed for extraction of fifteen organic sulphur compounds from aqueous samples. The analysis of the extracted them was performed by gas chromatography equipped with mass spectrometry and/or flame photometric detectors. 3.3 µL of organic solvent located in the lu...

متن کامل

Preparation of basil seed mucilage aerogels loaded with paclitaxel nanoparticles by the combination of phase inversion technique and gas antisolvent process

Objective(S): In this work, paclitaxel (PX), a promising anticancer drug, was loaded in the basil seed mucilage (BSM) aerogels by implementation of supercritical carbon dioxide (SC-CO2) technology. Then, the effects of operating conditions were studied on the PX mean particle size (MPS), particle size distribution (PSD) and drug loading efficiency (DLE). <stron...

متن کامل

Multi-Residue Analysis of Pesticides in Pistachio Using Gas Chromatography-Mass Spectrometry (GC/MS)

Background: Analysis of pesticide residues in food and other environmental commodities have become an essential requirement for consumers, producers, food inspectors and authorities. This study is focused on validation of an accurate, rapid and reliable method for multi-residual analysis of pesticides in pistachio as a strategic crop for export and one of the main nuts in Iranian food basket.Me...

متن کامل

Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....

متن کامل

Screening Method for Mononitrotoluenes in Natural Waters Using Magnetic Solvent Bar Liquid-Phase Micro-extraction Followed by Gas Chromatography-Flame Ionization Detection

A simple andefficient hollow fiber-based method,viz magnetic solvent bar liquid-phasemicroextraction (MSB-LPME) combined with gas chromatography-flame ionization detection (GCFID)has been successfully developed for the trace determination of mononitrotoluenes (MNTs) innatural water samples. The analytes were extracted from sample solution to the organic solventimmobilize...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017