Deconvolution-based partial volume correction in Raclopride-PET and Monte Carlo comparison to MR-based method

نویسندگان

  • Jussi Tohka
  • Anthonin Reilhac
چکیده

In this work, we evaluated three iterative deconvolution algorithms and compared their performance to partial volume (PV) correction based on structural imaging in brain positron emission tomography (PET) using a database of Monte Carlo-simulated images. We limited our interest to quantitative radioligand PET imaging, particularly to (11)C-Raclopride and striatal imaging. The studied deconvolution methods included Richardson-Lucy, reblurred Van Cittert, and reblurred Van Cittert with the total variation regularization. We studied the bias and variance of the regional estimates of binding potential (BP) values and the accuracy of regional TACs as a function of the applied image processing. The resolution/noise tradeoff in parametric BP images was addressed as well. The regional BP values and TACs obtained by deconvolution were almost as accurate than those by structural imaging-based PV correction (GTM method) when the ideal volumes of interests (VOIs) were used to extract TACs from the images. For deconvolution methods, the ideal VOIs were slightly eroded from the exact anatomical VOI to limit the bias due to tissue fraction effect which is not corrected for by deconvolution-based methods. For the GTM method, the ideal VOIs were the exact anatomical VOIs. The BP values and TACs by deconvolution were less affected by segmentation and registration errors than those with the GTM-based PV correction. The BP estimates and TACs with deconvolution-based PV correction were more accurate than BPs and TACs derived without PV correction. The parametric images obtained by the deconvolution-based PV correction showed considerably improved resolution with only slightly increased noise level compared to the case with no PV correction. The reblurred Van Cittert method was the best of the studied deconvolution methods. We conclude that the deconvolution is an interesting alternative to structural imaging-based PV correction as it leads to quantification results of similar accuracy, and it is less prone to registration and segmentation errors than structural imaging-based PV correction. Moreover, PV-corrected parametric images can be readily computed based on deconvolved dynamic images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

An MR image-guided, voxel-based partial volume correction method for PET images.

PURPOSE Partial volume effect in positron emission tomography (PET) can cause incorrect quantification of radiopharmaceutical uptake in functional imaging. A PET partial volume correction method is presented to attenuate partial volume blurring and to yield voxel-based corrected PET images. METHODS By modeling partial volume effect as a convolution of point spread function of the PET scanner,...

متن کامل

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

Comparison of PET template-based and MRI-based image processing in the quantitative analysis of C11-raclopride PET

BACKGROUND Quantitative measures of 11C-raclopride receptor binding can be used as a correlate of postsynaptic D2 receptor density in the striatum, allowing 11C-raclopride positron emission tomography (PET) to be used for the differentiation of Parkinson's disease from atypical parkinsonian syndromes. Comparison with reference values is recommended to establish a reliable diagnosis. A PET templ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 39 4  شماره 

صفحات  -

تاریخ انتشار 2008