Initial evaluation of cystatin C measurement by particle-enhanced immunonephelometry on the Behring nephelometer systems (BNA, BN II).

نویسندگان

  • H Finney
  • D J Newman
  • W Gruber
  • P Merle
  • C P Price
چکیده

Serum cystatin C has been suggested as a new marker of glomerular filtration rate (GFR). We describe a fully automated and rapid particle-enhanced nephelometric immunoassay (PENIA) for measuring serum cystatin C on the Behring nephelometer systems (BNA, BN II). Each sample is analyzed in 6 min with as many as 75 samples per batch. The assay covers the range 0.23-7.25 mg/L, up to seven times the upper limit of normal. The intra- and interassay imprecision are < 3.3% and < 4.5%, respectively. There is absolute linearity across the assay range (r2 = 0.997), with analytical recovery by cystatin C addition between 95% and 109% (mean 102%). Hemoglobin (< or = 8.0 g/L), bilirubin (< or = 488 microL), triglycerides (< or = 23 mmol/L), rheumatoid factor (< or = 2000 kIU/L), and myeloma paraprotein (< or = 41 g/L) do not interfere with the assay. This assay agreed well with an in-house particle-enhanced turbidimetric immunoassay (PETIA) (mean difference = 1.73 +/- 2.10) and a commercial PETIA (mean difference = 1.13 +/- 0.86). This is a new assay by which cystatin C may be effectively used as a marker of GFR estimation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evidence of temperature-dependent interference in an immunonephelometric assay by monoclonal IgM.

To the Editor: Interference by monoclonal IgM has been described in the immunonephelometric assays of C-reactive protein, antistreptolysin O, ferritin, and complement C4 (1–6). This report describes the interference by monoclonal IgM (IgMk) in the immunonephelometric assays of apolipoproteins A-I and B, haptoglobin, and immunoglobulins A and G. The patient, a man 54 years of age, was admitted t...

متن کامل

An improved automated immunoassay for C-reactive protein on the Dimension® clinical chemistry system

Recent clinical data indicate that the measurement of the concentration of C-reactive protein (CRP) requires a higher sensitivity and wider dynamic range than most of the current methods can offer. Our goal was to develop a totally automated and highly sensitive CRP assay with an extended range on the Dimension((R)) clinical chemistry system based on particle-enhanced turbidimetric-immunoassay ...

متن کامل

Measurement of proteins with the Behring Nephelometer. A multicentre evaluation.

The selective multi-protein analyser Behring Nephelometer was examined according to the ECCLS guidelines in a multicentre evaluation involving five laboratories. IgG, IgA, IgM, C-reactive protein, C3c, C4, apolipoprotein A-I and B were measured in serum, and albumin and IgG were measured in cerebrospinal fluid. All values obtained were included in the evaluation without correcting for outliers....

متن کامل

Beta-trace protein is not better than cystatin C as an indicator of reduced glomerular filtration rate.

To the Editor: Recent studies suggest that serum cystatin C [reviewed in Refs. (1, 2)] and -trace protein (3, 4) identify reductions in glomerular filtration rate (GFR) better than creatinine does. Woitas et al. (5 ) compared for the first time the diagnostic performance of cystatin C, -trace protein, 2microglobulin, and creatinine in relation to inulin clearance. They noted that we reported a ...

متن کامل

Standardization for four protein analytes with the Behring Nephelometer.

Owing to the generally higher values observed in the initial establishment of immunoglobulins (Ig) G, A, and M assays with the Behring Nephelometer, we elected to verify five commercial protein calibrators. This initial verification was performed by standardizing the Behring Nephelometer with the World Health Organization (WHO) International Reference Preparation for Human Serum Immunoglobulins...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 43 6 Pt 1  شماره 

صفحات  -