A combined solenoid-surface RF coil for high-resolution whole-brain rat imaging on a 3.0 Tesla clinical MR scanner.
نویسندگان
چکیده
Rat brain models effectively simulate a multitude of human neurological disorders. Improvements in coil design have facilitated the wider utilization of rat brain models by enabling the utilization of clinical MR scanners for image acquisition. In this study, a novel coil design, subsequently referred to as the rat brain coil, is described that exploits and combines the strengths of both solenoids and surface coils into a simple, multichannel, receive-only coil dedicated to whole-brain rat imaging on a 3.0 T clinical MR scanner. Compared with a multiturn solenoid mouse body coil, a 3-cm surface coil, a modified Helmholtz coil, and a phased-array surface coil, the rat brain coil improved signal-to-noise ratio by approximately 72, 61, 78, and 242%, respectively. Effects of the rat brain coil on amplitudes of static field and radiofrequency field uniformity were similar to each of the other coils. In vivo, whole-brain images of an adult male rat were acquired with a T(2)-weighted spin-echo sequence using an isotropic acquisition resolution of 0.25 x 0.25 x 0.25 mm(3) in 60.6 min. Multiplanar images of the in vivo rat brain with identification of anatomic structures are presented. Improvement in signal-to-noise ratio afforded by the rat brain coil may broaden experiments that utilize clinical MR scanners for in vivo image acquisition.
منابع مشابه
Application of an End-user Friendly Cryogenic Coil for in Vivo High Resolution Medical Image on 3t Whole Body Scanner a Novel Liquid Nitrogen Cryostat and Coil for High-resolution In-vivo Imaging on a 3 Tesla Whole Body Scanner
The design and operation of a receive-only liquid nitrogen (LN2) cooled coil and cryostat suitable for medical image on 3T whole body MR scanner is presented. The coil size, optimised for murine imaging, was determined by using electromagnetic (EM) simulations. This process is therefore easier and more cost-effective than building a range of coils. A non-magnetic cryostat suitable for small ani...
متن کاملReproducibility of small animal cine and scar cardiac magnetic resonance imaging using a clinical 3.0 tesla system
BACKGROUND To evaluate the inter-study, inter-reader and intra-reader reproducibility of cardiac cine and scar imaging in rats using a clinical 3.0 Tesla magnetic resonance (MR) system. METHODS Thirty-three adult rats (Sprague-Dawley) were imaged 24 hours after surgical occlusion of the left anterior descending coronary artery using a 3.0 Tesla clinical MR scanner (Philips Healthcare, Best, T...
متن کاملDevelopment of a 0.014-inch anti-solenoid loop coil: Toward intracoronary 3.0T MRI and interventions
PURPOSE: Atherosclerotic coronary artery disease is the main cause of heart attack. Unlike plaques in carotid arteries, the atherosclerotic plaques in coronary arteries are difficult to be detected using conventional MRI techniques with surface coils. To solve this problem, a 0.014-inch intracoronary MR imaging-guidewire (a loopless RF coil) was invented, which enabled to generate intracoronary...
متن کاملIn vivo multiple-mouse MRI at 7 Tesla.
We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost ar...
متن کاملIn vivo fiber tracking in the rabbit brain on a clinical 3T MRI system
Introduction: The white matter structure of the developing rabbit brain has been studied recently in great detail in vitro by using high-resolution diffusion tensor imaging and tractography [1] with an animal MR scanner. Both the simple structure of the lissencephalic rabbit brain and the reproducibility of ex vivo fiber tracking make the rabbit model a powerful tool for neuroscience investigat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 64 3 شماره
صفحات -
تاریخ انتشار 2010