Imaging study on the optic canal using sixty four-slice spiral computed tomography.
نویسندگان
چکیده
BACKGROUND Rapid advances in multislice computed tomography (MSCT) technology facilitate accurate clinical imaging. The newly developed 64-slice CT increases temporal and spatial resolution efficiently. PURPOSE The purpose of this study is to evaluate the application of 64 slice spiral computed tomography (CT) on the imaging of the normal optics canal. METHODS AND MATERIALS 100 healthy adults were investigated using 64 slice spiral CT. The optics canal was scanned, reconstructed and examined. RESULTS Among the four walls of the optic canal, the medial wall is the longest one. The upper wall and outer wall are inferior to the medial wall while the inferior wall is the shortest one. All the data accomplished by the 64 slice CT was consistent with the results of previous reports using other methods. CONCLUSION The results suggested that the 64 slice spiral CT could be a valuable and accurate method for measuring the length of optics canal walls.
منابع مشابه
Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study
Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...
متن کاملA Computed Tomographic Study of Canal Variations in Maxillary & Mandibular first Premolar Teeth in Jaipur Population – An in vitro Study
The present study was carried out to observe root canal variations in maxillary and mandibular first premolar teeth in the local population using spiral computed tomography. Sixty, each of well formed maxillary and mandibular first premolar teeth without any carious lesions were used in this study. They were placed in 5% sodium hypochlorite solution for 30 minutes for the removal of organic deb...
متن کاملEffect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro
Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...
متن کاملOptimization of Parameters in 16-slice CT-scan Protocols for Reduction of the Absorbed Dose
Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...
متن کاملPatient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode
Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of clinical and experimental medicine
دوره 8 11 شماره
صفحات -
تاریخ انتشار 2015