Biointerface multiparametric study of intraocular lens acrylic materials.

نویسندگان

  • Virginie Bertrand
  • Dimitriya Bozukova
  • Tiziana Svaldo Lanero
  • Yi-Shiang Huang
  • Daureen Schol
  • Nancy Rosière
  • Magda Grauwels
  • Anne-Sophie Duwez
  • Christine Jérôme
  • Christophe Pagnoulle
  • Edwin De Pauw
  • Marie-Claire De Pauw-Gillet
چکیده

PURPOSE To compare hydrophilic and hydrophobic acrylic materials designed for intraocular lenses in a multiparametric investigation in a liquid environment to highlight their properties in terms of adhesion forces, lens epithelial cell (LEC) adhesion, and tissue response as indicators of the risk for posterior capsule opacification (PCO) development. SETTING University of Liège, Liège, Belgium. DESIGN Experimental study. METHODS The hydrophobicity and surface adhesion force were assessed using contact-angle and atomic force microscopy measurements. The bioadhesiveness of the disks and the tissue response were determined by in vitro experiments using bovine serum albumin and porcine LECs and by in vivo rabbit subcutaneous implantation, respectively. RESULTS Increasing surface hydrophobicity led to a greater surface-adhesion force and greater LEC adhesion. After 1 month, the rabbit subcutaneous implants showed a similar thin layer of fibrous capsule surrounding the disks without extensive inflammation. A layer of rounded cells in contact with disks was detected on the hydrophobic samples only. CONCLUSIONS Hydrophobic acrylic disks that have been associated with a reduced risk for PCO in clinical studies showed increased tackiness. FINANCIAL DISCLOSURES Proprietary or commercial disclosures are listed after the references.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study.

AIMS To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule. METHODS Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between th...

متن کامل

Treatment of ophidism-induced bilateral canine cataract by extracapsular lens extraction and intraocular lens implantation

The aim of this study was to report a new cause of cataract, namely snake bite induced cataract in a dog. A 3-year-old male mongrel dog was referred to our clinic for the assessment of cataract in both eyes. The dog was bitten by a snake nearly 4 months ago. A 40 dioptre acrylic lens with 13 mm haptics was implanted into the lens capsule. In the left eye, posterior synechia was detected in the ...

متن کامل

Biofilm formation by Staphylococcus epidermidis on intraocular lens material.

PURPOSE To compare biofilm formation by Staphylococcus epidermidis on different intraocular lens (IOL) materials. METHODS The S. epidermidis strains, ATCC 12228 (American Type Culture Collection) and ATCC 35984 (biofilm-producer) were used. Biofilms were cultivated on disks of different IOL materials: silicone, PMMA (polymethylmethacrylate), acrylic, or MPC (2-methacryloyloxyethyl phosphorylc...

متن کامل

Assessment of new-generation glistening-free hydrophobic acrylic intraocular lens material.

PURPOSE To determine the hydrophobic, antiglistening, and bioadhesiveness properties of a new polymer, GF raw material, and to determine the suitability of this material for use in intraocular lenses (IOLs). SETTING University of Liege, Liege, Belgium. DESIGN Experimental study. METHODS Intraocular lenses made of the new hydrophobic acrylic material were tested and compared with reference...

متن کامل

Long-Term Stability of Diffractive Multifocal Intraocular Lenses: Contralateral Comparison between Silicone and Acrylic Materials

Objective: To compare visual function stability between silicone and hydrophobic acrylic materials of diffractive multifocal intraocular lenses (MF-IOLs). Methods: This retrospective study reviewed clinical records of 10 patients who received a silicone MF-IOL in the first eye and hydrophobic acrylic lens in the fellow eye. Intra-individual differences in logMAR corrected distance visual acuity...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 40 9  شماره 

صفحات  -

تاریخ انتشار 2014