Ipsilateral proximal and shaft femoral fractures
نویسندگان
چکیده
PURPOSE To study the management and evaluate anatomical and functional outcomes of patients with ipsilateral proximal and shaft femoral fractures. METHODS A retrospective, descriptive and analytic study lasted for ten years and a half ranging from January 1, 2005 to June 30, 2015. The following parameters were studied: epidemiology, fracture characteristics, therapeutic, anatomical and functional outcomes. The correlation between different parameters was analyzed with Fischer test. The significant threshold was defined for p value <0.05. RESULTS Ten medical files were registered. There were 7 men and 3 women, with a sex ratio of 2.33. The average age was 46 years (range: 29-62 years). It was about traffic road accidents in all cases. Motorcycle-motorcycle and motorcycle-car collision were most frequent. Average admission delay was 7 h (range: 1.5-24 h). Left side was most reached in 8 cases. According to Garden classification, there was type III cervical fracture in 2 cases, type II in 1 case and type IV in 1 case. According to Ender classification, there was type I trochanteric fracture in 3 cases, type VI in 2 cases and type VII in 1 case. According to AO classification, there was type A shaft fracture in 6 cases (A2 in 4 cases and A3 in 2 cases), type B in 2 cases (B1 in 1 case and B2 in 1 case) and type C in 2 cases (C1 in 1 case and C2 in 1 case). Average surgical delay was 28.7 days (range: 11-61 days). For proximal femoral fracture, Moore prosthesis was used in 1 case, blade plate 130° in 2 cases, long Gamma nail in 4 cases, double screwing in 2 cases and dynamic hip screw in 1 case. For shaft femoral fracture, blade plate 95° was used in 3 cases, low compressive plate in 2 cases. Osseous contention was achieved in 4 cases with long Gamma nail and in 1 case with long blade plate 130°. Nonunion of cervical fracture was achieved in 2 cases. The average osseous healing delay was 5.14 months (range: 3-12 months) for proximal femoral fracture and 5 months (range: 3-8 months) for shaft femoral fractures. According to Friedman and Wyman criteria, functional results were good in 4 cases, average in 4 cases and bad in 2 cases. Regarding implants, healing delay showed no statistic difference between one-implant group and two-implant group (p = 0.52), and among the patients with different functional outcomes (p = 0.52). Functional outcomes showed no statistic difference between one-implant group and two-implant group (p = 0.46). CONCLUSION Ipsilateral proximal and shaft femoral fractures are relatively uncommon in our daily activities. It is difficult to recognize proximal femoral fractures which are unnoticed. Results are generally good if the doctors take the two fractures into account in the management.
منابع مشابه
Concomitant ipsilateral femoral neck and shaft fractures--analysis of cases.
Concomitant ipsilateral shaft and femoral neck or pertrochanteric fractures are uncommon. They result from high-energy traumas and the mechanism of injury is usually complex. The proximal fracture is often not displaced and may be hardly visible on x-rays. Overlooking the proximal fracture may result in therapeutic problems. The best method of treatment is by closed stabilization of both fractu...
متن کاملUse of reconstruction nails to manage ipsilateral displaced femoral neck-shaft fractures: assessment of a new approach.
PURPOSE Owing to unpredictable femoral neck reduction, reconstruction nails are not suitable for fixation of group 3 ipsilateral femoral neck-shaft fractures. We developed a new one-step fixation technique to overcome this problem. This study aims to assess this new technique at the Orthopaedic Department, Chi-Mei Foundation Medical Center, Tainan. METHODS Of 31 consecutive patients with femo...
متن کاملReverse distal femoral locking compression plate a salvage option in nonunion of proximal femoral fractures
BACKGROUND When primary fixation of proximal femoral fractures with implants fails, revision osteosynthesis may be challenging. Tracts of previous implants and remaining insufficient bone stock in the proximal femur pose unique problems for the treatment. Intramedullary implants like proximal femoral nail (PFN) or surface implants like Dynamic Condylar Screw (DCS) are few of the described impla...
متن کاملTreatment of ipsilateral femoral neck and shaft fractures.
OBJECTIVE To investigate the clinical characteristics, treatment options and causes of misdiagnosis of ipsilateral femoral neck and shaft fractures. METHODS Among 20 patients with ipsilateral femoral neck and shaft fractures, 19 were treated operatively and 1 was treated conservatively. Sixteen cases of femoral shaft fractures were treated by open reduction and internal fixation with compress...
متن کاملInjuries Associated with Femoral Shaft Fractures with Special Emphasis on Occult Injuries
Background: Fractures of the femoral shaft are mostly the result of high-energy accidents that also cause multiple trauma injuries, in particular ipsilateral knee and hip injuries. The purpose of this study was to investigate the incidence of injuries associated with femoral shaft fractures and how many of them were undetected. Methods: We studied 148 patients (150 femoral shaft fractures) wi...
متن کاملElastic Stable Intramedullary Nailing of Femoral Shaft Fracture-Experience in 48 Children
Background: Femoral shaft fractures are an incapacitating pediatric injury accounting for 1.6% of all pediatric bonyinjuries. Management of these fractures is largely directed by age, fracture pattern, associated injuries, built of the childand socioeconomic status of the family. We retrospectively evaluated the use of elastic stable intramedullary nail (ESIN)in surgical management of femoral s...