A comparative test method to determine thermal resistance under field conditions

نویسندگان

  • M. T. BOMBERG
  • Y. S. MUZYCHKA
  • D. G. STEVENS
  • M. K. KUMARAN
چکیده

This paper presents the development and application ofa test method to determine thermal resistance of a material under transient conditions. The method consists oftesting two material slabs placed in contact with one another, one of them being a reference material with known dependence of thermal conductivity and heat capacity on temperature and the other being a test specimen whose thermal properties are to be determined. Thermocouples are placed on each surface of the standard and reference materials to measure temperatures during a transient heat transport process. These temperatures are used as the boundary conditions in a series of calculations. First, the heat flux across the contact surface between the reference and the test specimen is calculated using a numerical algorithm to solve the heat transfer equation through the reference material. Then, imposing the requirement of heat flux continuity at the contact surface, corresponding values of thermal conductivity and heat capacity of the test specimen are calculated with an iterative technique. These calculations, done as a function of time, result in a set of thermal properties of the test specimen for the range of boundary conditions imposed during the transient process. This method can be used under transient conditions of either laboratory or field testing. Of particular interest is its application to examine effects of aging (effect of time) and weathering (effect of time and environmental conditions) on thermally insulating foams. For instance, in this research, the reference and tested specimens are *Senior Researchers at the National Research Council of Canada. **Summer Assistants at the National Research Council of Canada. J. THERMAL 'NSUL. AND 8LDG. ENVS. Volume 18October 1994 163 1065-2744/94/02 0163-19 $06.00/0 ©1994 Technomic Publishing Co., Inc. 164 M. T. BOMBERG ET Al. placed in an exposure box representing a conventional roofing assembly and the change in the thermal properties of the test specimens is determined.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

نیازهای گرمایی زنبور سیاه مغزخوار پسته (Eurytoma plotnikovi Nikolskaya) پس از زمستان گذرانی

In winter 1997 severely infested pistachio nuts were collected from orchards in Borkhar district of Isfahan to determine minimum threshold temperature and thermal constants. Minimum threshold temperatures were calculated according to rate of development or X-intercept method and the least coefficient of variation method. Thermal constants were calculated for different developmental stages in th...

متن کامل

نیازهای گرمایی زنبور سیاه مغزخوار پسته (Eurytoma plotnikovi Nikolskaya) پس از زمستان گذرانی

In winter 1997 severely infested pistachio nuts were collected from orchards in Borkhar district of Isfahan to determine minimum threshold temperature and thermal constants. Minimum threshold temperatures were calculated according to rate of development or X-intercept method and the least coefficient of variation method. Thermal constants were calculated for different developmental stages in th...

متن کامل

A Comparative Solution of Natural Convection in an Open Cavity using Different Boundary Conditions via Lattice Boltzmann Method

A Lattice Boltzmann method is applied to demonstrate the comparison results of simulating natural convection in an open end cavity using different hydrodynamic and thermal boundary conditions. The Prandtl number in the present simulation is 0.71, Rayleigh numbers are 104,105 and 106 and viscosities are selected 0.02 and 0.05. On-Grid bounce-back method with first-order accuracy and non-slip met...

متن کامل

Hydroponics Roofs for Saving Energy of Green Schools in the Cold and Dry climate of Iran: A Comparative Study between Two Broad and Modular Hydroponic Green Roofs

Green schools are a new type of school, in which the use of renewable energy is less than that of conventional schools. In this regard, nowadays, adding green layers to the roof of schools, in addition to increasing the Students' communication with nature, energy saving has improved in these spaces. However, to improve energy saving yield, the priority of these types of roofs in different clima...

متن کامل

Study of Degradation of Dry Cooling Tower Performance under Wind Conditions and Method for Tower Efficiency Enhancement (RESEARCH NOTE)

Wind affects adversely the cooling tower thermal performance. A field investigation was carried out to study the thermal performance of Heller cooling towers under wind conditions, involving measurement of wind velocity and its direction around the cooling tower, and obtaining water flow rates and temperatures at the cooling tower inlet and outlet. Results show that air suction at the tower top...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011