Near-Infrared Spectroscopy versus Transcranial Doppler-Based Monitoring in Carotid Endarterectomy

نویسندگان

  • Jun Woo Cho
  • Jae Seok Jang
چکیده

Background Proper monitoring of cerebral perfusion during carotid artery surgery is crucial for determining if a shunt is needed. We compared the safety and reliability of near-infrared spectroscopy (NIRS) with transcranial Doppler (TCD) for cerebral monitoring. Methods This single-center, retrospective review was conducted on patients who underwent carotid endarterectomy (CEA) using selective shunt-based TCD or NIRS at Daegu Catholic University Medical Center from November 2009 to June 2016. Postoperative complications were the primary outcome, and the distribution of risk factors between the 2 groups was compared. Results The medical records of 74 patients (45 TCD, 29 NIRS) were reviewed. The demographic characteristics were similar between the 2 groups. One TCD patient died within the 30-day postoperative period. Postoperative stroke (n=4, p=0.15) and neurologic complications (n=10, p=0.005) were only reported in the TCD group. Shunt usage was 44.4% and 10.3% in the TCD and NIRS groups, respectively (p=0.002). Conclusion NIRS-based selective shunting during CEA seems to be safe and reliable for monitoring cerebral perfusion in terms of postoperative stroke and neurologic symptoms. It also reduces unnecessary shunt usage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials.

BACKGROUND This study compares the accuracy of cerebral monitoring systems in detecting cerebral ischemia during carotid endarterectomy. METHODS The authors compared transcranial Doppler sonography (TCD), near-infrared spectroscopy (NIRS), stump pressure (SP) measurement, and somatosensory evoked potentials (SEP) in 48 patients undergoing carotid surgery during regional anesthesia. Cerebral i...

متن کامل

Monitoring cerebral ischemia during carotid endarterectomy and stenting

Current therapy for carotid stenosis mainly includes carotid endarterectomy and endovascular stenting, which may incur procedure-related cerebral ischemia. Several methods have been employed for monitoring cerebral ischemia during surgery, such as awake neurocognitive assessment, electroencephalography, evoked potentials, transcranial Doppler, carotid stump pressure, and near infrared spectrosc...

متن کامل

Evaluation of a near-infrared spectrometer (NIRO 300) for the detection of intracranial oxygenation changes in the adult head.

BACKGROUND AND PURPOSE The clinical application of intracranial near-infrared spectroscopy in adults has been hampered by concerns over contamination from extracranial tissues. The NIRO 300 (Hamamatsu Photonics) provides continuous online measurements of hemoglobin and cytochrome oxidase concentrations and a calculated tissue oxygen index (TOI). The present study seeks confirmation of the anato...

متن کامل

Carotid endarterectomy improves cognitive function in patients with exhausted cerebrovascular reserve.

OBJECTIVE To investigate changes in cognitive function following carotid endarterectomy (CEA). DESIGN Prospective study with controls. METHODS CEA patients (n=159) were compared to a urology surgery control group (n=20). In CEA patients cerebrovascular reserve (CVR) was measured preoperatively. During surgery emboli and blood flow velocity in the middle cerebral artery were measured by tran...

متن کامل

Phenylephrine versus ephedrine on cerebral perfusion during carotid endarterectomy (PEPPER): study protocol for a randomized controlled trial

BACKGROUND Intraoperative arterial hypotension can lead to severe complications in patients undergoing carotid endarterectomy, in particular if cerebral auto-regulation is impaired. Short-acting agents, such as phenylephrine or ephedrine, commonly used to correct intra-operative hypotension, have different hemodynamic effects. Recently, it was reported that, in healthy anesthetized subjects wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 50  شماره 

صفحات  -

تاریخ انتشار 2017