Effect of anterior chamber depth on the choice of intraocular lens calculation formula
نویسندگان
چکیده
PURPOSE To investigate the effect of anterior chamber depth (ACD) on the refractive outcomes of the SRK/T, Holladay 1, Hoffer Q and Haigis formulae in short, normal, long and extremely long eyes. METHODS This retrospective study involved patients who had uncomplicated cataract surgery. Preoperative axial length (AL) was divided into four subgroups: short (< 22.00 mm), normal (22.00-24.49 mm), long (24.50-25.99 mm), extremely long (≥ 26.00 mm). Preoperative ACD was divided into three subgroups: < 2.5, 2.50-3.49, and ≥ 3.5 mm. Median absolute errors (MedAEs) predicted by the SRK/T, Holladay 1, Hoffer Q and Haigis formulae were compared with the Friedman test. Post-hoc analysis involved the Wilcoxon signed rank test with a Bonferroni adjustment. Correlations between ACD and the predictive refractive errors of the four formulas were analyzed. RESULTS In short eyes with an ACD < 2.5 mm, the Haigis formula revealed the highest MedAE. The difference in MedAE with the Hoffer Q formula (which had the lowest MedAE) was statistically significant (P = 0.002). In normal eyes, the Haigis formula significantly differed from the Holladay 1 (P = 0.002) and Hoffer Q (P = 0.005) formulae in the ACD < 2.5 mm group. In long eyes and extremely long eyes with an ACD ≥ 3.5 mm, the differences in MedAEs were statistically significant (P = 0.018, P = 0.001, respectively) and the Haigis formula had the lowest MedAEs in both subgroups (0.29 D, 0.30 D, respectively). In the total of 1,123 eyes, refractive errors predicted by the Haigis formula showed a significant negative correlation with the ACD (R2 = 0.002, P = 0.047). CONCLUSIONS The Hoffer Q formula is preferred over other formulae in short eyes with an ACD shallower than 2.5 mm. In short and normal eyes with an ACD < 2.5 mm the Haigis formula might underestimate ELP. The Haigis formula is the preferred choice in eyes with an AL ≥ 24.5 mm and an ACD ≥ 3.5 mm.
منابع مشابه
Accuracy of Intraocular Lens Power Calculation Formulas in Primary Angle Closure Glaucoma
PURPOSE To compare the accuracy of intraocular lens (IOL) power calculation formulas in eyes with primary angle closure glaucoma (ACG). METHODS This retrospective study compared the refractive outcomes of 63 eyes with primary ACG with the results of 93 eyes with normal open angles undergoing uneventful cataract surgery. Anterior segment biometry including anterior chamber depth, axial length,...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کامل[Trial of new intraocular lens power calculation following phototherapeutic keratectomy].
We reviewed the SRK-II method and introduce a new equation to calculate the intraocular lens (IOL) power for eyes which underwent laser phototherapeutic keratectomy (PTK). The Gullstrand series was used to determine the power and the radius of curvature of planoconvex IOLs which alter the focal point from the cornea to reach the conjugate point on the retina. The radius of anterior corneal curv...
متن کاملAxial length , anterior chamber depth and lens thickness : Their intercorrelations in black South Africans
The ability to obtain accurate measurement of ocular biometric dimensions, such as axial length (AL), anterior chamber depth (ACD) and crystalline lens thickness (LT), is essential in many clinical and research applications. For example, AL is used clinically for intraocular lens (IOL) power calculation prior to cataract and refractive surgery1 and to diagnose ocular conditions such as staphylo...
متن کاملChanges in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation
OBJECTIVES To compare anterior chamber depth (ACD) changes after phacoemulsification surgery in patients with pseudoexfoliation syndrome (PEX) and normal patients using an anterior segment imaging method. Another aim of this study was to evaluate the effect of these changes on the accuracy of intraocular lens (IOL) power calculation and postoperative refraction. MATERIALS AND METHODS Twenty-t...
متن کاملEffect of pupillary dilation on Haigis formula-calculated intraocular lens power measurement by using optical biometry
PURPOSE The purpose of this study was to evaluate the effect of pupillary dilation on the Haigis formula-calculated intraocular lens (IOL) power and ocular biometry measurements by using IOLMaster(®). METHODS A prospective study was performed for biometry measurements of 373 eyes of 192 healthy subjects using the IOLMaster at the outpatient department of King Chulalongkorn Memorial Hospital f...
متن کامل