In vitro study of the diagnostic performance of the Spectra Caries Detection Aid.

نویسندگان

  • Kenneth Markowitz
  • Archana Gutta
  • Hisham E Merdad
  • Gerald Guzy
  • Glenn Rosivack
چکیده

OBJECTIVE The Spectra Caries Detection Aid is a fluorescent camera (FC) caries detector device that has been demonstrated to detect occlusal caries extending into dentin with good sensitivity and specificity. This in vitro study examined the diagnostic performance of this device with the goal of defining the numerical reading that best indicates that a tooth has dentin caries. METHODS Ninety extracted human third molars, that either appeared clinically intact or had early occlusal caries, were used. Teeth were photographed then analyzed using the Spectra Caries detector. Following Spectra readings, the teeth were sectioned perpendicular to the long axis of the tooth. Cuts were made in such a way as to expose the dentino-enamel junction below the pits and fissures. The sectioned teeth were scored as being caries-free, having enamel caries, or dentin caries. Using each tooth's Spectra reading and histological diagnosis, the sensitivity and specificity for various potential dentin caries cut-off values were calculated. Also, the receiver operator curve (ROC) was plotted and the area under the curve calculated. RESULTS At the manufacture's recommended cut-off for dentin caries diagnosis of 2, the sensitivity is 0.68 and the specificity is 0.78. At a lower cut-off value in the study reported here of 1.8, it was observed that the sensitivity is higher at 0.87, but that the specificity is lower at 0.7. The overall diagnostic performance of the Spectra is good with an ROC area under the curve of 0.82. CONCLUSION Although lower cut-off values may have higher sensitivity, the use of the manufacture's established cut-off of 2 will result in fewer instances where dentin caries will be diagnosed incorrectly. The use of higher thresholds will discourage restorative treatment of early lesions that are best managed by sealants or other preventive approaches.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)

Background and Aim: Considering the importance of detection of secondary caries, the adverse consequences of false positive and false negative diagnoses and the gap of information in the diagnostic efficacy of digital sensors in detection of secondary caries, this in vitro study sought to compare the diagnostic efficacy of two different resolutions of radiographs obtained by photostimulable pho...

متن کامل

In vitro Comparison of Conventional Film and Direct Digital Radiography in Proximal Caries Detection

Introduction: Various systems for intraoral digital radiography have been available as an alternative to film–based radiography. In consideration of several advantages of digital radiography such as less patient absorbed dose, manipulation of im‌age quality and elimination of processing, it has been extensively used in different fields of denti‌stry in recent years. The purpose of this study wa...

متن کامل

Diagnostic Accuracy of Digitized Images Using Different Resolution Settings of Digital Camera in Detection of Proximal Caries

Objective: When none of digital systems and scanners is accessible and it is essential to have digitized images of conventional radiographs, digital cameras can be used. The Aim of this study was to investigate whether digital images obtained by different resolutions of a digital camera are matched to the original radiographs in evaluation of caries. Methods: In this diagnostic accuracy in v...

متن کامل

Efficacy of the Edge Enhancement Filter of Digital Radiography in the Detection of Proximal Enamel Caries in Premolars

Background and Aim: Considering the significance of the detection of proximal caries and the limited information available on the diagnostic value of digital radiography after the use of enhancement filters, this in-vitro study sought to compare the diagnostic value of digital radiography with and without the use of the edge enhancement (EE) filter in the detection of proximal enamel caries in ...

متن کامل

In Vivo Diagnostic Accuracy of Digital Radiography in the Detection of Secondary Caries in Anterior Teeth

Background and Aim: Secondary caries are a common challenge for dentists. Many researchers have evaluated the accuracy of digital radiographic systems in the detection of secondary caries and have reported controversial results. Therefore, the aim of this in vivo study was to determine the diagnostic accuracy of digital radiography in the detection of secondary caries in anterior teeth. Mate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of clinical dentistry

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2015