Protamine immobilization and heparin adsorption on the protamine-bound cellulose fiber membrane.

نویسندگان

  • J S Kim
  • A J Yang
  • V C Yang
چکیده

Immobilization of protamine to the inner lumen of cellulose hollow fibers has been shown useful in preventing both heparin- and protamine-induced complications during an extracorporeal blood circulation procedure. The current study examined the effects of variables on the immobilization of protamine to cyanogen bromide (CNBr)-activated cellulose hollow fibers. The degree of protamine immobilization was controlled by three independent parameters: the amount of CNBr used during the activation process, the duration of the coupling process, and the protamine concentration in the coupling solution. By the adjustment of these parameters, cellulose fibers containing desired amounts of immobilized protamine (ranging from 1 to 20 mg of immobilized protamine per gram of dry fibers) were readily prepared.Heparin adsorption to the protamine-bound cellulose fibers was also examined. The adsorption isotherm followed a Langmuir adsorption model. The amount of heparin adsorbed was dependent on both the heparin concentration in the substrate solution and the protamine loading on the fibers. The Langmuir adsorption constant K was estimated to be 0.37 +/- 0.06 mL/mg, whereas the saturation capacity Q(s) of the protamine-bound fibers increased with increasing the protamine loading.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Poly-L-lysine amplification of protamine immobilization and heparin adsorption.

We previously reported the development of a cellulose fiber based blood filter device containing immobilized protamine (termed protamine filter) that could be used to control both heparin- and protamine-induced complications during extracorporeal therapy. To achieve enhanced heparin adsorption on the fibers, we examined the possibility of utilizing the poly-L-lysine based amplification method t...

متن کامل

Comparison between complications of vascular surgery procedures with and without aPPT assessment and protamine sulfate reversal

 Abstract Background: Thrombosis will occur due to contact of blood with unepithelialized surfaces after vascular clamping and also blood stasis during vascular surgery. Heparin is administered to prevent thrombosis. The aPTT test is used for assurance of the anticoagulative effect of heparin. At the end of the operation heparin is neutralized by protamine sulfate in some centers. In this study...

متن کامل

Effect of RBCs on the activation of human complement by heparin-protamine complexes.

Complement activation on red cells by heparin-protamine complexes was studied by using whole human serum. C3 bound to red cells was measured by radiolabeled monoclonal antibody to C3, and fluid-phase C5a was determined by radioimmunoassay. Heparin and protamine in clinically relevant concentrations caused the binding of C3 to red cell membranes, and the measurement of C3 binding provided a sens...

متن کامل

Heparin and homogeneous model heparin oligosaccharides form distinct complexes with protamine: Light scattering and zeta potential analysis.

Large multimolecular complexes of heparin with positively charged proteins such as platelet factor 4 (PF4) or protamine can initiate immune responses associated with heparin use in patients, including the most significant adverse event, heparin-induced thrombocytopenia (HIT). Current evidence suggests that platelet-activating antibodies that recognize large multi-molecular complexes (300-700kDa...

متن کامل

Improved protamine-sensitive membrane electrode for monitoring heparin concentrations in whole blood via protamine titration.

An improved protamine-sensitive electrode based on a polymeric membrane doped with the charged ion exchanger dinonylnaphthalenesulfonate (DNNS) is used for monitoring heparin concentrations in whole blood. The electrode exhibits significant nonequilibrium potentiometric response to polycationic protamine over the concentration range of 0.5-20 mg/L in undiluted whole-blood samples. The sensor ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biotechnology and bioengineering

دوره 39 4  شماره 

صفحات  -

تاریخ انتشار 1992