Two-dimensional high spatial-resolution dosimeter using europium doped potassium chloride: a feasibility study.
نویسندگان
چکیده
Recent research has shown that KCl:Eu²⁺ has great potential for use in megavoltage radiation therapy dosimetry because this material exhibits excellent storage performance and is reusable due to strong radiation hardness. This work reports the authors' attempts to fabricate 2D KCl:Eu²⁺ storage phosphor films (SPFs) using both a physical vapor deposition (PVD) method and a tape casting method. X-ray diffraction analysis showed that a 10 µm thick PVD sample was composed of highly crystalline KCl. No additional phases were observed, suggesting that the europium activator had been completely incorporated into the KCl matrix. Photostimulated luminescence and photoluminescence spectra suggested that F (Cl(-)) centers were the electron storage centers post x-ray irradiation and that Eu²⁺ cations acted as luminescence centers in the photostimulation process. The 150 µm thick casted KCl:Eu²⁺ SPF showed sub-millimeter spatial-resolution. Monte Carlo simulations further demonstrated that the admixture of 20% KCl:Eu²⁺ and 80% low Z polymer binder exhibited almost no energy-dependence in a 6 MV beam. KCl:Eu²⁺ pellet samples showed a large dynamic range from 0.01 cGy to 60 Gy dose-to-water, and saturated at approximately 500 Gy as a result of KCl's intrinsic high radiation hardness. Taken together, this work provides strong evidence that KCl:Eu²⁺-based SPF with associated readout apparatus could result in a novel electronic film system that has all the desirable features associated with classic radiographic film and, importantly, water equivalence and the capability of permanent identification of each detector.
منابع مشابه
Skin dose measurement for patients using imaging plates in interventional radiology procedures.
A method using europium-doped BaFBr imaging plates (IPs) has been developed to estimate and map values of entrance skin doses during interventional radiology (IR). IPs offer many advantages for measuring the entrance skin dose because they have a wide dynamic range (up to 100 Gy), provide high spatial resolution as a detector of two-dimensional images, and can be used repeatedly. The entrance s...
متن کاملCo Irradiation Chamber
Due to its excellent remote measurability and high spatial resolution, the fiber optic-based radiation dosimeter has been extensively explored for its usability in medical applications by several researchers [1-2]. In the previous work [3,4], we reported the result of our investigation on feasibility of a photon dosimeter constructed with a BGO(Bi4Ge3O12) or GSO(Gd2SiO5) scintillator piece coup...
متن کاملTwo-Dimetional Hydraulic Simulation of Floods using the LISFLOOD-FP Raster Model (A Case Study: The Shemshak Watershed, Tehran Province)
LISFLOOD-FP belongs to a new generation of hydrodynamic models of flood simulation, which is implemented by a digital elevation map for the river and the waterways, route information and flow rates The LISFLOOD-FP features are two-dimensional hydraulic models: 1. based on raster 2. large scale 3. ease of formulation and high computational efficiency 4. simplicity of use 5. spatial adjustmen...
متن کاملSynthesis, characterization and sonophotocatalytic degradation of an azo dye on Europium doped cadmium selenide nanoparticles
In this study, Eu-doped CdSe nanoparticles with variable Eu3+ content were synthesized by a simple sonochemical method. Eu3+ substitution into the structure of CdSe resulted in a material with new physical properties, composition and morphology. The synthesized nanoparticles were characterized by powder X-ray diffraction (XRD), scanning electron microscopy (SEM), X-ray photoelectron spectroscop...
متن کاملA new approach to contrast enhancement in MAGICA gel dosimeter image with MRI technique
parameters that have to be measured in gel dosimetry. However, the resolution in gel is strongly dependant on gel composition. Selection of optimum method in dose response readout and proper values of parameters can result in noise reduction as well as improvement of contrast, and spatial resolution considerably. Materials and Methods: MAGICA polymer gel dosimeters were manufactured and irradia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 59 8 شماره
صفحات -
تاریخ انتشار 2014