Biodegradable poly-L/D-lactide (P(L/D)LA) 96/4 joint scaffold arthroplasty is a recently clinically introduced concept in the reconstruction of small joints, however its histology and function in vivo is unknown. In this experimental study on 11 minipigs the fifth metacarpophalangeal joints were reconstructed using a P(L/D)LA 96/4 joint scaffold or Swanson silicone implant. They were evaluated until 3 years. The P(L/D)LA 96/4 joint scaffold formed a porous interposition spacer, which maintained the arthroplasty space and induced fibrous tissue in-growth in situ. No differences were found in the range of motion or arthroplasty space width between the study groups. The P(L/D)LA 96/4 joint scaffold was initially filled with vascular, loose connective tissue. Along with degradation of the scaffold, the in-grown connective tissue matured and condensed turning into dense fibrous connective tissue. After 3 years, the P(L/D)LA 96/4 joint scaffold had almost completely degraded and been replaced by dense fibrous connective tissue. These findings indicate that P(L/D)LA 96/4 joint scaffold arthroplasty leads to the formation of a functional fibrous joint. The avoidance of permanent foreign material makes the biodegradable joint scaffold an attractive alternative for small joint arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implant-Based Prosthetic Reconstruction in Patients with Congenital Ear Defects (Technical Note)

Background and aims: Loss of all or part of the ear is one of the significant defects in the head and neck area (regardless of the cause) that can result from trauma, cancer, congenital diseases, or surgery to remove benign tumors. These defects can be reconstructed with the help of surgical procedures or cosmetic prostheses. However, due to the complex structure of the ear, reconstructive surg...

متن کامل

Bioreconstructive joint scaffold implant arthroplasty in metacarpophalangeal joints: short-term results of a new treatment concept in rheumatoid arthritis patients.

Swanson silicone implant is the "gold standard" of metacarpophalangeal joint reconstruction in rheumatoid arthritis (RA) patients. However, durability problems of silicone implants have led us to develop a new technique based on bioreconstructive implants. PLA96 (poly-L,D-lactide copolymer, L:D ratio of 96:4) scaffolds were engineered. Bioabsorption and substitution of porous PLA96 scaffold wit...

متن کامل

Use of Chitosan Conduit for Bridging Small-Gap Peripheral Nerve Defect in Sciatic Nerve Transection Model of Rat

Objective-To evaluate effect of chitosan conduit for peripheral nerve regeneration using sciatic nerve transection model in rat Design- Experimental in vivo study. Animals- Sixty healthy male Wistar rats. Procedures-The rats were divided into four experimental groups (n=15) randomly. In sham group the left sciatic nerve was exposed through a gluteal muscle incision and after careful...

متن کامل

Overview on Vascular Tissue Engineering: Progress and Challenges

Today, vascular diseases such as atherosclerosis are one of the leading causes of death in the world and the prevalence of it in older societies is rising. The current treatments for repair of cardiovascular function include organ transplantation, surgical reconstruction, mechanical or artificial devices, or the use of metabolic products. Although these methods are commonly used, they did not g...

متن کامل

Bioreconstructive poly-L/D-lactide implant compared with Swanson prosthesis in metacarpophalangeal joint arthroplasty in rheumatoid patients: a randomized clinical trial.

It was hypothesized that the bioresorbable interposition implant might offer a viable alternative to conventional silicone implant arthroplasty in rheumatoid metacarpophalangeal joint destruction. A randomized clinical study was performed to compare a stemless poly-L/D-lactide copolymer 96 : 4 (PLDLA) implant with the Swanson silicone implant. Results in 52 patients (53 hands and 175 joints) at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomaterials

دوره 29 6  شماره 

صفحات  -

تاریخ انتشار 2008