Electret ion chamber-based passive radon-thoron discriminative monitors.
نویسندگان
چکیده
Electret ion chambers (EICs), commercially available under brand name E-PERM(®), are widely used for measuring indoor and outdoor (222)Rn concentrations in air. These are designed to respond only to (222)Rn and not to (220)Rn by restricting diffusional entry area. Such radon EIC (R EIC) monitors are modified by increasing the entry area to allow (220)Rn, in addition to (222)Rn. Such modified units are called RT EIC. When a set of R and RT EICs are collocated, it is possible to discriminate and measure both radon and thoron concentrations, using appropriate calibration factors (CFs) and algorithms. The EICs come in different volumes, providing different sensitivities. The thoron CFs for 58-, 210- and 960-ml volume R and RT pairs are, respectively, 2.8-, 18.7- and 89-V drop per (kBq m(-3) d ), respectively. These provide much wider sensitivities and ranges compared to alpha track-based passive radon-thoron discriminative monitors.
منابع مشابه
MEASUREMENT OF ""Rn (THORON) USING ELECTRET ION CHAMBERS
Recently there has been an increased interest in the measurement of airborne ""Rn (thoron). Such measurements are particularly targeted in areas rich in thorium, and in facilities processing thorium compounds and associated radioactive wastes. Standard electret ion chambers @-PERMSR)* designed for making indoor and outdoor "^Rn (radon) measurement have very little response to "¡R (thoron). How...
متن کاملComparative Measurements of Radon Concentration in Soil Using Passive and Active Methods in High Level Natural Radiation Area (HLNRA) of Ramsar
Background: Radon and its daughters are amongst the most important sources of natural exposure in the world. Soil is one of the significant sources of radon/thoron due to both radium and thorium so that the emanated thoron from it may cause increased uncertainties in radon measurements. Recently, a diffusion chamber has been designed and optimized for passive discriminative measurements of rado...
متن کاملCalibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD
Background: Separate radon and thoron measurements in soil are very important in assessment of internal exposure due to inhalation of such radioactive gases. Materials and Methods: In this study, a low cost, small size, passive diffusion chamber has been developed for simple measurement of Radon-222 and Radon-220(Thoron) gases separately in soil. The diffusion chamber consists of two films and ...
متن کاملComparative Measurements of Radon Concentration in Soil Using Passive and Active Methods in High Level Natural Radiation Area (HLNRA) of Ramsar
BACKGROUND Radon and its daughters are amongst the most important sources of natural exposure in the world. Soil is one of the significant sources of radon/thoron due to both radium and thorium so that the emanated thoron from it may cause increased uncertainties in radon measurements. Recently, a diffusion chamber has been designed and optimized for passive discriminative measurements of radon...
متن کاملElevation Correction Factors K)r E-perm(r) Radon Monitors
E-PERM(R) radon monitors are based on the principle of electret ion chambers and these are usually calibrated in a standard radon chamber located at sea level. Corrections are needed if these are used in elevations other than sea level. These were experimentally determined for three models of commercially available electret ion chambers (E-PERMS(R)) as functions of elevation above sea level. . ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Radiation protection dosimetry
دوره 141 4 شماره
صفحات -
تاریخ انتشار 2010