Humidification of the airways. Adequate for function and integrity?
نویسنده
چکیده
gastrointestinal hemorrhage by irradiation with a power neo-dymium-YAG laser. 8 Cortese DA, Kensey JH. Endoscopic management of lung cancer with hematoporphyrin derivative phototherapy. Photoradiation therapy in the treatment of advanced cancer of the trachea and bronchus. Chest (in press) 11 Dougherty TJ. Photoradiation therapy (PRT) of malignant tumors. In: Critical review in oncology-hematology. he upper respiratory tract serves as an air condi-T t i o n i n g system; particulate matter is entrapped while inspired air is warmed and humidified prior to entry into the major airways. Turbulent flow through the nose and pharynx propels solid particles towards the surface, enhances convective transfer of heat from the mucosa, and increases the apparent surface area of exposure for evaporation of water vapor into the air stream. Because the nasal mucosa becomes cooled in the process, exhaled gas, which is fully humidified at body temperature, gives up water vapor to the cooler surface and the effluent gas temperature is reduced to 32-34°C.' Fully saturated air at this temperature contains 10.2 mg/L less water vapor than alveolar gas. Water and heat recapture by this mechanism conserves 20-25 percent of insensible losses during normal breathing in temperate atmospheric conditions.' The administration of relatively dry anesthetic gases and oxygen-enriched mixtures via an endotracheal tube obliges the lower respiratory tract to perform these functions. The potential hazard of greater heat and water losses, as well as structural damage was appreciated early in tracheotomized patients, and external application of humidity was demonstrated to alleviate excess mucus production and encrustation of secretions. Much subsequent study has revealed the sensitivity of the tracheobronchial tree to incompletely humidified gas. Cessation of ciliary beating occurs within ten minutes of exposure of the trachea to 50 percent relative humidity.' Tracheal mucus velocity, studied in intact dogs,5 was reduced by half after one hour of breathing dessicated room air and completely ceased after three hours. Subsequent rehumidification of the airway rapidly restored tracheal mucus velocity, but histologic evidence demonstrated that extensive inflammation and sloughing of ciliated epithelium in the trachea and bronchi were present despite the functional restoration observed. Cytologic studies in anesthetized human subjects confirmed that damage to the tracheal epithelium occurs within two hours of administration of dry gases through an endotracheal tube, whereas gases at 60 percent relative humidity produce no damageas However , air at 60 percent relative humidity delivered through an endotracheal tube reaches only 83 percent …
منابع مشابه
Delivery of molecular versus particulate water in spontaneously breathing tracheotomized patients.
BACKGROUND Adequate humidification of inspired gas with active or passive humidifiers is a standard of care for tracheotomized patients. In this study, a comparison is made between the tracheal climate after tracheobronchial humidification either with molecular water (via a vaporizing humidifier) or particulate water (via spray) in spontaneously breathing tracheotomized patients. METHODS We p...
متن کاملHumidification on Ventilated Patients: Heated Humidifications or Heat and Moisture Exchangers?
The normal physiology of conditioning of inspired gases is altered when the patient requires an artificial airway access and an invasive mechanical ventilation (IMV). The endotracheal tube (ETT) removes the natural mechanisms of filtration, humidification and warming of inspired air. Despite the noninvasive ventilation (NIMV) in the upper airways, humidification of inspired gas may not be optim...
متن کاملMulti-Objective Optimization of the Humidification-Dehumidification Desalination System for Productivity and Size
The humidification-dehumidification system is one of the desalination technologies that can utilize non-fossil thermal sources and requires insignificant input energy. This system is usually suitable for rural areas and places far from the main sources of energy. The purpose of this study is to obtain the most suitable working conditions and dimensions of this system. In this research, thermody...
متن کاملPrediction of the Effect of Polymer Membrane Composition in a Dry Air Humidification Process via Neural Network Modeling
Utilization of membrane humidifiers is one of the methods commonly used to humidify reactant gases in polymer electrolyte membrane fuel cells (PEMFC). In this study, polymeric porous membranes with different compositions were prepared to be used in a membrane humidifier module and were employed in a humidification test. Three different neural network models were developed to investigate several...
متن کاملY-piece temperature and humidification during mechanical ventilation.
BACKGROUND Practitioners often presume there is adequate humidification in the ventilator circuit if the Y-piece is at a specified temperature, but control of Y-piece temperature may be inadequate to ensure adequate humidification. METHODS In an in vitro bench model we measured water-vapor delivery with several heated humidification setups and a wide range of minute volume (V (E)) values. The...
متن کاملHumidification for Patients with Artificial Airways
Introduction Normal Mechanisms of Heat and Moisture Exchange in the Respiratory Tract High-Flow Humidifiers Pass-over Humidifiers Wick Humidifiers Bubble Humidifiers Artificial Noses Moisture Output Resistance Dead Space Additives Cost Choosing an Artificial Nose Active Hygroscopic Heat and Moisture Exchangers HME-Booster Use of Humidification Devices During Mechanical Ventilation Use of Heated...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 84 5 شماره
صفحات -
تاریخ انتشار 1983