Simulated Prosthesis Overlay for Patient-Specific Planning of Transcatheter Aortic Valve Implantation Procedures.
نویسندگان
چکیده
OBJECTIVE We tested the hypothesis that simulated three-dimensional prosthesis overlay procedure planning may support valve selection in transcatheter aortic valve implantation (TAVI) procedures. METHODS Preoperative multidimensional computed tomography (MDCT) data sets from 81 consecutive TAVI patients were included in the study. A planning tool was developed, which semiautomatically creates a three-dimensional model of the aortic root from these data. Three-dimensional templates of the commonly used TAVI implants are spatially registered with the patient data and presented as graphic overlay. Fourteen physicians used the tool to perform retrospective planning of TAVI procedures. Results of prosthesis sizing were compared with the prosthesis size used in the actually performed procedure, and the patients were accordingly divided into three groups: those with equal size (concordance with retrospective planning), oversizing (retrospective planning of a smaller prosthesis), and undersizing (retrospective planning of a larger prosthesis). RESULTS In the oversizing group, 85% of the patients had new pacemaker implantation. In the undersizing group, in 66%, at least mild paravalvular leakage was observed (greater than grade 1 in one third of the cases). In 46% of the patients in the equal-size group, neither of these complications was observed. CONCLUSIONS Three-dimensional prosthesis overlay in MDCT-derived patient data for patient-specific planning of TAVI procedures is feasible. It may improve valve selection compared with two-dimensional MDCT planning and thus yield better outcomes.
منابع مشابه
Image-based decision-making treatment of degenerated mitroflow and trifecta prostheses.
PURPOSE In the present report we describe our clinical experience using specific image-based decision making and anatomic considerations for transcatheter valve-in-valve (ViV) implantation in degenerated xenografts with their pericardial leaflets externally mounted around the stent (Mitroflow [SORIN Group, Milan, Italy] or Trifecta [St. Jude Medical, St Paul, MN]). This design seems to increase...
متن کاملSuccessful Transfemoral Edwards Sapien Aortic Valve Implantation in a Patient with Previous Mitral Valve Replacement
Transcatheter aortic valve implantation (TAVI) is a new method for patients with severe aortic stenosis at high surgical risk, such as previous cardiac surgery. The presence of mechanical mitral prosthesis might complicate TAVI because of possible interference between the both prosthesis. Some reports have already demonstrated the feasibility of TAVI in such patients. We report our experience w...
متن کاملSimulation of transcatheter aortic valve implantation: a patient-specific finite element approach.
Until recently, heart valve failure has been treated adopting open-heart surgical techniques and cardiopulmonary bypass. However, over the last decade, minimally invasive procedures have been developed to avoid high risks associated with conventional open-chest valve replacement techniques. Such a recent and innovative procedure represents an optimal field for conducting investigations through ...
متن کاملReview of patient-specific simulations of transcatheter aortic valve implantation
Transcatheter Aortic Valve Implantation (TAVI) accounts for one of the most promising new cardiovascular procedures. This minimally invasive technique is still at its early stage and is constantly developing thanks to imaging techniques, computer science, biomechanics and technologies of prosthesis and delivery tools. As a result, patient-specific simulation can find an exciting playground in T...
متن کاملSystem to Guide Transcatheter Aortic Valve Implantations Based on Interventional C-Arm CT Imaging
Transcatheter aortic valve implantation is an emerging technique to be applied in patients with aortic valve defects. Angiographic and fluoroscopic X-ray imaging with a C-arm system is crucial in these minimally invasive procedures. We describe a prototypical system based on the ability to acquire a 3D C-arm CT image during transcatheter aortic valve implantations. It supports the physician in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Innovations
دوره 10 5 شماره
صفحات -
تاریخ انتشار 2015